Key result
Inadvertent transvenous permanent left ventricular pacing through an atrial septal defect resulted in no systemic embolic phenomena over 43 months of follow-up on antiplatelet therapy.
Case Report (n=1)
Inadvertent transvenous permanent left ventricular pacing through an atrial septal defect can be managed with antiplatelet therapy without systemic embolic phenomena over a 43-month follow-up.
Answers are grounded in this paper and cite their sources.
Supports antiplatelet management in rare inadvertent LV pacing via ASD; leaves open need for prospective data on embolic risk.
This case report presents a patient who inadvertently received transvenous permanent left ventricular pacing through an unexpected atrial septal defect. This lead malpositioning was proved by two-dimensional and transesophageal echocardiography. The abnormal pattern of electric activation was demonstrated by radionuclide phase image analysis. He has been followed up for a total of forty-three months with antiplatelet therapy and has been free from systemic embolic phenomena. A simple and readily available method that could lead to early recognition of lead malpositioning is reiterated and the various causes, methods of detection, and prognosis of left ventricular pacing are discussed.
No takes yet. Share an insight, caveat, or question.
Lee et al. (1995) conducted a case report in Inadvertent transvenous permanent left ventricular pacing (n=1). Transvenous permanent left ventricular pacing was evaluated on Systemic embolic phenomena. Inadvertent transvenous permanent left ventricular pacing through an atrial septal defect resulted in no systemic embolic phenomena over 43 months of follow-up on antiplatelet therapy.
Synapse has enriched 10 related papers. Consider them for comparative context: