Key result
Epicardial CIEDs in pediatric CHD are linked to ~4-fold higher cumulative ionizing radiation versus controls.
Why the study?
To determine whether paediatric congenital heart disease patients with epicardial CIEDs receive high cumulative effective doses of ionizing radiation from medical imaging tests.
Does the presence of epicardial CIEDs increase the cumulative effective dose of ionizing radiation from medical imaging in paediatric congenital heart disease patients?
Case-Control (n=68)
Does the presence of epicardial CIEDs increase the cumulative effective dose of ionizing radiation from medical imaging in paediatric congenital heart disease patients?
Absolute Event Rate: 6.9% vs 1.72%
p-value: p=0.0018
Paediatric CHD patients with epicardial CIEDs receive significantly higher cumulative ionizing radiation doses from medical imaging, largely due to the substitution of MRI with CT.
May warrant radiation-aware imaging protocols in paediatric CHD with epicardial CIEDs; leaves open prospective confirmation of mitigation strategies.
Aims To determine whether paediatric congenital heart disease (CHD) patients with epicardial cardiac implantable electronic devices (CIEDs) receive high cumulative effective doses (CEDs) of ionizing radiation from medical imaging tests. Methods and results We compared 28 paediatric CHD patients with epicardial CIEDs (cases) against 40 patients with no CIED matched by age at operation, sex, surgical era, and CHD diagnosis (controls). We performed a retrospective review of radiation exposure from medical imaging exams between 2006 and 2022. Radiation dose from computed tomography (CT) and X-ray radiography was calculated using the National Cancer Institute Radiation Dosimetry Tool. We performed univariate analysis to compare the CED between the two groups. In the case subgroup, we convened experts’ review to adjudicate the prevalence of CT exams that should have been performed with magnetic resonance imaging (MRI) in the absence of a CIED. Children (median age 2.5 years at implant) with CIEDs received significantly higher median CED compared with matched controls (6.90 vs. 1.72 mSv, P = 0.0018). In cases, expert adjudication showed that 80% of the CT exams would have been performed with MRI in the absence of a CIED. This resulted, on average, a five-fold increase in the effective dose (ED) from post-lead implant CTs. Conclusion Paediatric CHD patients with CIED received four times higher CED than matched controls. Improved access to medical imaging tests without ionizing radiation, such as MRI, could potentially reduce the ED in CIED patients by up to five times.
No takes yet. Share an insight, caveat, or question.
Aboyewa et al. (2024) conducted a case-control in Paediatric congenital heart disease (n=68). Epicardial cardiac implantable electronic devices (CIEDs) vs. No CIED was evaluated on Median cumulative effective dose (CED) of ionizing radiation (p=0.0018). Paediatric CHD patients with epicardial CIEDs received significantly higher median cumulative effective doses of ionizing radiation than matched controls (6.90 vs 1.72 mSv, P=0.0018).