Key result
Higher airway pressure linked to ~5.8-fold higher odds of left atrial NSSIC per 10 cmH2O.
Why the study?
Microbubble testing during the Valsalva manoeuvre is essential for diagnosing patent foramen ovale, but non-smoke spontaneous individual contrast may mimic right-to-left shunt, motivating an investigation of its association with graded positive airway pressure during simulated Valsalva loading.
Does higher positive airway pressure during simulated Valsalva loading increase the occurrence of non-smoke spontaneous individual contrast (NSSIC) in patients undergoing transcatheter PFO closure?
Observational (n=35)
No
Does higher positive airway pressure during simulated Valsalva loading increase the occurrence of non-smoke spontaneous individual contrast (NSSIC) in patients undergoing transcatheter PFO closure?
Higher positive airway pressure during simulated Valsalva loading significantly increases non-smoke spontaneous individual contrast in both atria, which must be recognized to avoid false-positive diagnosis of right-to-left shunt during PFO testing.
Answers are grounded in this paper and cite their sources.
Higher simulated Valsalva pressures were associated with LA NSSIC; hypothesis-generating and should not yet alter PFO bubble study protocols.
Background Microbubble testing during the Valsalva manoeuvre (VM) is essential for diagnosing patent foramen ovale (PFO), but non-smoke spontaneous individual contrast (NSSIC) may mimic right-to-left shunt (RLS). We investigated the association between graded positive airway pressure during simulated Valsalva loading and NSSIC. Methods This single-centre retrospective observational study included 35 consecutive patients undergoing transcatheter PFO closure between December 2024 and November 2025. Under general anaesthesia, positive airway pressures of 10, 20, and 30 cmH2O were applied for 10 seconds and abruptly released without contrast injection. Repeated measurements were analysed using mixed-effects logistic regression for left atrial (LA) NSSIC and generalized estimating equations for right atrial (RA) NSSIC. Results RA NSSIC occurred in 26/33 (78.8%), 34/35 (97.1%), and 34/35 (97.1%) at 10, 20, and 30 cmH2O. Compared with 10 cmH2O, the odds were higher at both 20 and 30 cmH2O (OR 8.985, 95% CI 1.332–60.62; p = 0.024 for both), with identical RA NSSIC status at 20 and 30 cmH2O. LA NSSIC increased from 3/33 (9.1%) to 11/35 (31.4%) and 23/35 (65.7%); each 10-cmH2O increase was associated with higher odds of LA NSSIC (OR 5.815, 95% CI 2.793–12.11; p < 0.001). Conclusions NSSIC occurrence increased with higher positive airway pressure during simulated Valsalva loading. Recognition of this phenomenon is important to avoid false-positive interpretation of RLS during microbubble testing for PFO.
No takes yet. Share an insight, caveat, or question.
Yamamoto et al. (2026) conducted an observational in Patent foramen ovale (PFO) (n=35). Graded positive airway pressure (20 and 30 cmH2O) during simulated Valsalva loading vs. Positive airway pressure of 10 cmH2O was evaluated on Left atrial non-smoke spontaneous individual contrast (LA NSSIC) (OR 5.815 per 10-cmH2O increase, 95% CI 2.793-12.11, p=<0.001). Each 10-cmH2O increase in positive airway pressure during simulated Valsalva loading increased odds of left atrial NSSIC.