Key result
Full coverage anti-G trousers with pressure breathing provided the greatest mean relaxed G tolerance during gradual (+6.2 Gz) and rapid (+6 Gz) onset runs compared to partial coverage systems.
Why the study?
UK Royal Air Force fast jet aircrew use three different anti-G systems, but little objective comparison of the G protection they provide existed.
Does full coverage AGT with PBG improve relaxed G tolerance and hemodynamic responses compared to partial coverage AGT in centrifuge-trained participants?
Does full coverage AGT with PBG improve relaxed G tolerance and hemodynamic responses compared to partial coverage AGT in centrifuge-trained participants?
p-value: p=<0.001
Full coverage anti-G trousers with pressure breathing provide superior G-protection and hemodynamic support compared to five-bladder partial coverage systems.
BACKGROUND: UK Royal Air Force fast jet aircrew use three different anti-G systems, however, little objective comparison of the G protection they provide exists. The G-protection afforded by each system and associated hemodynamic responses were investigated. METHODS: Ten subjects performed centrifuge acceleration exposures using Mk-10 (S1) and Mk-4 (S2) five-bladder anti-G trousers (AGT) and full coverage AGT plus pressure breathing for G-protection (PBG; S3). Measurements of relaxed G tolerance (RGT), eye-level blood pressure (BP eye ), lower body blood volume (LBV), stroke volume (SV) and total peripheral resistance (TPR) were made during gradual onset runs (GOR) and rapid onset runs (ROR). The subjective effort required to maintain clear vision at +7 and +8 G z provided an indication of the protection provided by the system. RESULTS: All systems moderated decreases in SV and BP eye and increases in LBV under increased +G z . S3 provided the greatest mean RGT during GOR (+6.2 G z ) and ROR (+6 G z ), reduced the effort required to maintain clear vision at up to +8 G z , prevented venous pooling and afforded the greatest rise in TPR. The majority of indices revealed no difference between S1 and S2 although RGT during the ROR was greater with S2 (+0.25 G z ). DISCUSSION: S3 effectively prevented pooling of blood in the lower limbs under +G z , despite the use of PBG, and offers an advantage over five-bladder AGT. Given the similarities of S1 and S2, it was unsurprising that the majority of indices measured were similar. The objective measurement of hemodynamic parameters provides useful information for comparing the G-protection provided by anti-G systems. Pollock RD, Firth RV, Storey JA, Phillips KE, Connolly DM, Green NDC, Stevenson AT. Hemodynamic responses and G protection afforded by three different anti-G systems. Aerosp Med Hum Perform. 2019; 90(11):925–933.
No takes yet. Share an insight, caveat, or question.
Pollock et al. (2019) studied Healthy volunteers (n=10). Full coverage anti-G trousers plus pressure breathing for G-protection (System 3) vs. Five-bladder partial coverage anti-G trousers (System 1 and System 2) was evaluated on Relaxed G tolerance during gradual onset runs (RGTGOR) (p=<0.001). Full coverage anti-G trousers with pressure breathing provided the greatest mean relaxed G tolerance during gradual (+6.2 Gz) and rapid (+6 Gz) onset runs compared to partial coverage systems.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: