Key result
Prolonged stent inflation significantly increased minimal stent diameter (SMD 0.42; 95% CI 0.25-0.59; P<0.001) and minimal stent area compared with shorter duration inflation.
Why the study?
Does prolonged stent inflation improve minimal stent diameter and area compared with short duration stent inflation in patients undergoing coronary stenting?
Meta-Analysis (n=341)
Does prolonged stent inflation improve minimal stent diameter and area compared with short duration stent inflation in patients undergoing coronary stenting?
Effect estimate: SMD 0.42 (95% CI 0.25-0.59)
Absolute Event Rate: 2.93% vs 2.72%
p-value: p=< 0.001
Prolonged stent inflation during deployment is associated with improved stent expansion, as measured by increased minimal stent diameter and area, compared to shorter inflation times.
Supports prolonged inflation to optimize stent expansion in PCI; extends meta-analytic evidence on deployment technique.
Background Despite evidence from individual studies suggesting that prolonged inflation improves coronary stent expansion, relatively shorter inflation times are commonly employed in clinical practice. Methods We performed an electronic search of PubMed, Web of Science, Cochrane, and CINAHL databases to retrieve outcome studies comparing prolonged versus short inflation times during stent deployment. Outcomes studied included minimal stent diameter (MSD) and minimal stent area (MSA). Standardized mean difference (SMD) was used to estimate the effect sizes for these continuous variables. Results Seven studies with a total of 341 patients (415 lesions; mean age 67.6 years; 82% male) were included. Drug‐eluting stents were used in 89 ± 15% of coronary lesions. Prolonged stent inflation was associated with increased minimal stent diameter (2.93 ± 0.34 mm vs. 2.72 ± 0.28 mm; SMD = 0.42; 95% CI 0.25–0.59; P < 0.001) and minimal stent area (5.99 ± 1.21 mm 2 vs. 5.17 ± 0.87 mm 2 ; SMD = 0.46; 95% CI 0.19–0.73; P = 0.001) compared with shorter duration stent inflation. This difference remained significant in sensitivity analyses that excluded studies with very prolonged inflation duration or multiple stent balloon inflations. Conclusion Despite differences in duration and methodology, prolonged stent inflation is associated with improved expansion compared with shorter duration. The effect of this optimization recommends randomized trials to determine whether long‐term outcomes can be improved by this simple technical modification.
No takes yet. Share an insight, caveat, or question.
Saad et al. (2018) conducted a meta-analysis in Coronary lesions requiring stent deployment (n=341). Prolonged stent inflation vs. Short stent inflation was evaluated on Minimal stent diameter (MSD) (SMD 0.42, 95% CI 0.25-0.59, p=< 0.001). Prolonged stent inflation significantly increased minimal stent diameter (SMD 0.42; 95% CI 0.25-0.59; P<0.001) and minimal stent area compared with shorter duration inflation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: