Key result
Increasing stent balloon inflation duration from 5 to 25 seconds significantly improved appropriate stent expansion from 24.0% to 68.0% (P<0.0001) in patients undergoing PCI.
Why the study?
Does longer duration of stent balloon inflation (15 or 25 seconds vs 5 seconds) improve stent expansion in patients undergoing PCI?
Does longer duration of stent balloon inflation (15 or 25 seconds vs 5 seconds) improve stent expansion in patients undergoing PCI?
Longer duration of stent balloon inflation (>25 seconds) significantly improves stent expansion compared to shorter durations during PCI.
Longer inflation may optimize stent expansion in PCI; hypothesis-generating and requires randomized confirmation before practice change.
OBJECTIVES: To assess the effect of the duration of stent inflation on stent expansion using digital stent enhancement (DSE). BACKGROUND: Optimal stent expansion and apposition to the vessel wall are of critical importance to optimize the results of percutaneous coronary intervention (PCI). However, it is not known if stent inflation duration impacts on stent expansion. METHODS: We performed a prospective cohort study in patients undergoing PCI. Quantitative coronary angiography and DSE data were analyzed. DSE was performed at 5, 15, and 25 sec during stent implantation, after target balloon inflation pressure was achieved. RESULTS: One hundred and four consecutive patients (150 lesions) were enrolled. The mean age was 66.9 ± 11.1 years. Complex lesions (ACC/AHA B2/C) occurred in 26.9%. Stents used: Cypher Select (54.1%), Xience V (30.6%), and Taxus Liberté (15.3%). The minimal stent diameter increased significantly with the duration of stent inflation: 2.60 ± 0.51, 2.76 ± 0.51, and 2.82 ± 0.52 mm at 5, 15, and 25 sec (P < 0.0001). Similarly, maximal stent diameter increased with the duration of stent inflation: 3.21 ± 0.51, 3.32 ± 0.52, and 3.36 ± 0.54 mm (P < 0.0001). The average stent diameter also increased with longer stent inflation (P < 0.0001). Using MUSIC criteria 24.0, 53.3, and 68.0% of stents were appropriately expanded at 5, 15, and 25 sec (P < 0.0001). CONCLUSIONS: The duration of stent balloon inflation has a significant impact on stent expansion. Stent deployment for >25 sec is recommended.
No takes yet. Share an insight, caveat, or question.
Hovasse et al. (2011) studied this question. Increasing stent balloon inflation duration from 5 to 25 seconds significantly improved appropriate stent expansion from 24.0% to 68.0% (P<0.0001) in patients undergoing PCI.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: