Key result
Closed-loop balloon-stent technique achieves targeted vessel occlusion in 100% of reported cases without complications.
Why the study?
Coronary vessel closure may be required in both emergent and elective settings during PCI, and the closed-loop balloon-stent technique offers a mechanical approach to targeted vessel occlusion using routinely available catheterization laboratory equipment.
Can the closed-loop balloon-stent technique achieve targeted vessel occlusion in emergent coronary perforation and elective saphenous vein graft closure during PCI?
Case Report (n=2)
Can the closed-loop balloon-stent technique achieve targeted vessel occlusion in emergent coronary perforation and elective saphenous vein graft closure during PCI?
This case report demonstrates that the closed-loop balloon-stent technique using standard catheterization laboratory equipment can achieve both emergent sealing of a distal coronary perforation and elective occlusion of a degenerated saphenous vein graft.
Answers are grounded in this paper and cite their sources.
May offer bailout option for coronary perforation and vein graft occlusion in PCI; leaves open prospective validation before adoption.
Coronary vessel closure may be required in both emergent and elective settings during percutaneous coronary intervention (PCI). The closed-loop balloon-stent technique is a previously described mechanical approach to targeted vessel occlusion using routinely available catheterization laboratory equipment. We report two distinct applications of this technique. In the first case, an Ellis type III distal right coronary artery (RCA) perforation occurring during PCI was treated with the closed-loop balloon-stent system, resulting in cessation of contrast extravasation despite minimal residual distal vessel opacification. Repeat angiography after guidewire withdrawal confirmed the absence of further extravasation, and no subsequent covered stent implantation or coil embolization was required. In the second case, a severely degenerated RCA saphenous vein graft was intentionally occluded following successful recanalization of the native RCA chronic total occlusion. Repeat angiography after guidewire withdrawal confirmed persistent graft occlusion. No device loss, clinically apparent embolization, or other complications attributable to the construct were observed in either case. These cases illustrate potential applications of the technique in selected emergent and elective settings. Its use requires consideration of balloon-component non-retrievability, embolization risk, and deliverability. Further clinical experience and follow-up are required to establish its safety, appropriate indications, and long-term durability.
No takes yet. Share an insight, caveat, or question.
Ürkmez et al. (2026) conducted a case report in Ellis type III distal right coronary artery perforation and severely degenerated RCA saphenous vein graft during percutaneous coronary intervention (n=2). Closed-loop balloon-stent technique was evaluated on Targeted coronary vessel occlusion (cessation of contrast extravasation or persistent graft occlusion). The closed-loop balloon-stent technique achieved targeted vessel occlusion in 2 of 2 cases, sealing a distal RCA perforation and occluding a saphenous vein graft without complications.