Key result
Continuous 7-day Holter monitoring revealed a 44% incidence of new-onset atrial fibrillation in medical ICU patients with septic shock, which was independently associated with older age and left ventricular ejection fraction <45%.
Observational (n=66)
No
New-onset atrial fibrillation is highly prevalent (44%) in patients with septic shock, particularly in older patients and those with reduced ejection fraction, but it does not appear to independently worsen short-term mortality.
Answers are grounded in this paper and cite their sources.
May prompt closer AF monitoring in septic shock without practice change; leaves open independent mortality effects.
PURPOSE: We investigated incidence, risk factors for new-onset atrial fibrillation (NAF), and prognostic impact during septic shock in medical Intensive Care Unit (ICU) patients. METHODS: Prospective, observational study in a university hospital. Consecutive patients from 03/2011 to 05/2013 with septic shock were eligible. Exclusion criteria were age <18 years, history of AF, transfer with prior septic shock. Included patients were equipped with long-duration (7 days) Holter ECG monitoring. NAF was defined as an AF episode lasting >30 seconds. Patient characteristics, infection criteria, cardiovascular parameters, severity of illness, support therapies were recorded. RESULTS: Among 66 patients, 29(44%) developed NAF; 10 (34%) would not have been diagnosed without Holter ECG monitoring. NAF patients were older, with more markers of heart failure (troponin and NT-pro-BNP), lower left ventricular ejection fraction (LVEF), longer QRS duration and more nonsustained supra ventricular arrhythmias (<30s) on day 1 than patients who maintained sinus rhythm. By multivariate analysis, age (OR: 1.06; p = 0.01) and LVEF<45% (OR: 13.01, p = 0.03) were associated with NAF. NAF did not predict 28 or 90 day mortality. CONCLUSIONS: NAF is common, especially in older patients, and is associated with low ejection fraction. We did not find NAF to be independently associated with higher mortality.
No takes yet. Share an insight, caveat, or question.
Guénancia et al. (2015) conducted an observational in Septic shock (n=66). 7-day Holter ECG monitoring was evaluated on Incidence of new-onset atrial fibrillation (NAF). Continuous 7-day Holter monitoring revealed a 44% incidence of new-onset atrial fibrillation in medical ICU patients with septic shock, which was independently associated with older age and left ventricular ejection fraction <45%.
Synapse has enriched 10 related papers. Consider them for comparative context: