Key result
Falling troponin patterns show a lower 53% positive predictive value for ruling in MI versus rising patterns.
Why the study?
Although mirroring different phases of myocardial injury, falling and rising troponin patterns are equally considered by most diagnostic algorithms for suspected MI without ST elevation.
Does the diagnostic performance of ESC 0/1-hour and 0/3-hour algorithms differ between falling and rising high-sensitivity cardiac troponin patterns in patients with suspected MI?
Cohort (n=3,647)
Does the diagnostic performance of ESC 0/1-hour and 0/3-hour algorithms differ between falling and rising high-sensitivity cardiac troponin patterns in patients with suspected MI?
Current ESC diagnostic algorithms for suspected MI have a significantly lower positive predictive value in patients with falling troponin patterns compared to rising patterns, highlighting a potential flaw in treating these patterns equally.
Answers are grounded in this paper and cite their sources.
Falling troponin patterns warrant caution with ESC 0/1-hour MI rule-in; leaves open need for pattern-specific prospective validation.
Background High‐sensitivity cardiac troponin (hs‐cTn)‐based diagnostic algorithms are recommended for the management of patients with suspected myocardial infarction (MI) without ST elevation. Although mirroring different phases of myocardial injury, falling and rising troponin patterns (FPs and RPs, respectively) are equally considered by most algorithms. We aimed to compare the performance of diagnostic protocols for RPs and FPs, separately. Methods and Results We pooled 2 prospective cohorts of patients with suspected MI and stratified patients to stable, FP, and RP during serial sampling separately for hs‐cTnI and hs‐cTnT and applied the European Society of Cardiology 0/1‐ and 0/3‐hour algorithms comparing the positive predictive values to rule in MI. Overall, 3523 patients were included in the hs‐cTnI study population. The positive predictive value for patients with an FP was significantly reduced compared with patients with an RP (0/1‐hour: FP, 53.3% [95% CI, 45.0–61.4] versus RP, 76.9 [95% CI, 71.6–81.7]; 0/3‐hour: FP, 56.9% [95% CI, 42.2–70.7] versus RP, 78.1% [95% CI, 74.0–81.8]). The proportion of patients in the observe zone was larger in the FP using 0/1‐hour (31.3% versus 55.8%) and 0/3‐hour (14.6% versus 38.6%) algorithms. Alternative cutoffs did not improve algorithm performances. Compared with stable hs‐cTn, the risk for death or MI was highest in those with an FP (adjusted hazard ratio [HR], hs‐cTnI 2.3 [95% CI, 1.7–3.2]; RP adjusted HR, hs‐cTnI 1.8 [95% CI, 1.4–2.4]). Findings were similar for hs‐cTnT tested in 3647 patients overall. Conclusions The positive predictive value to rule in MI by the European Society of Cardiology 0/1‐ and 0/3‐hour algorithms is significantly lower in patients with FP than RP. These are at highest risk for incident death or MI. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifiers: NCT02355457, NCT03227159.
No takes yet. Share an insight, caveat, or question.
Haller et al. (2023) conducted a cohort in Suspected myocardial infarction without ST elevation (n=3,647). Falling troponin pattern (FP) vs. Rising troponin pattern (RP) was evaluated on Positive predictive value to rule in MI (0/1-hour algorithm). The positive predictive value to rule in MI using the ESC 0/1-hour algorithm was lower in patients with falling versus rising high-sensitivity cardiac troponin patterns.
Synapse has enriched 10 related papers. Consider them for comparative context: