Key result
Tissue Doppler imaging detected diastolic dysfunction in up to 42% of children with end-stage renal disease, compared to only 5% using conventional echocardiography.
Why the study?
Does tissue Doppler imaging improve the detection of diastolic dysfunction compared to conventional echocardiography in children with end-stage renal disease?
Case-Control (n=114)
Does tissue Doppler imaging improve the detection of diastolic dysfunction compared to conventional echocardiography in children with end-stage renal disease?
Tissue Doppler imaging is more sensitive and reproducible than conventional echocardiography for detecting early diastolic dysfunction in children with end-stage renal disease.
Answers are grounded in this paper and cite their sources.
Should not yet change practice for diastolic assessment in children with ESRD; supports further validation of tissue Doppler imaging.
INTRODUCTION: Early detection of cardiovascular disease in children with end-stage renal disease is essential in order to prevent cardiovascular morbidity and mortality in early adulthood. Tissue Doppler imaging has shown to be a promising method to detect and quantify subtle abnormalities in diastolic function. We therefore compared assessment of diastolic function by conventional echocardiography and tissue Doppler imaging. METHODS: We performed conventional echocardiography and tissue Doppler imaging in 38 children with end-stage renal disease and 76 healthy controls. We compared outcomes on parameters related to diastolic function (E/a ratio for conventional echocardiography and E/E' ratio for tissue Doppler imaging) for both groups using multiple linear regression analysis. Diastolic dysfunction was defined as E/a ratio <1 or E/E' ratio > 95th percentile for age. To assess the intra-observer reproducibility, the coefficient of variation was calculated. RESULTS: Children with end-stage renal disease had on average a lower E/a ratio (p = 0.004) and a higher mitral and septal E/E' ratio (both p < 0.001) compared with controls. In all, two children with end-stage renal disease (5%) had diastolic dysfunction according to the E/a ratio, 11 according to the mitral E/E' ratio (29%), and 16 according to the septal E/E' ratio (42%) compared with none of the controls (p = 0.109, p < 0.001, and p < 0.001, respectively). The coefficients of variation of the mitral (7%) and septal E/E' ratio (4%) were smaller than the coefficient of variation of the E/a ratio (11%). CONCLUSIONS: Tissue Doppler imaging is a more sensitive and reliable method to detect diastolic dysfunction than conventional E/a ratio in children with end-stage renal disease.
No takes yet. Share an insight, caveat, or question.
Schoenmaker et al. (2013) conducted a case-control in end-stage renal disease (n=114). Tissue Doppler imaging vs. Conventional echocardiography was evaluated on Diastolic dysfunction (E/a ratio <1 or E/E' ratio > 95th percentile for age). Tissue Doppler imaging detected diastolic dysfunction in up to 42% of children with end-stage renal disease, compared to only 5% using conventional echocardiography.
Synapse has enriched 10 related papers. Consider them for comparative context: