Key result
Biolimus-A9-eluting BP-DES were noninferior to everolimus-eluting DP-DES for cardiac death, MI, and target-vessel revascularization at 2 years.
Why the study?
Does biolimus-A9-eluting biodegradable-polymer drug-eluting stents reduce combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization in patients with acute or stable coronary disease needing stents ≥3.0 mm compared to everolimus-eluting durable-polymer stents or bare-metal stents?
RCT (n=2,291)
Yes
Does biolimus-A9-eluting biodegradable-polymer drug-eluting stents reduce combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization in patients with acute or stable coronary disease needing stents ≥3.0 mm compared to everolimus-eluting durable-polymer stents or bare-metal stents?
Biodegradable-polymer biolimus-eluting stents were noninferior to durable-polymer everolimus-eluting stents and superior to bare-metal stents for large vessel stenting, but did not improve long-term safety or reduce very late stent thrombosis, challenging the concept that durable polymers are the primary cause of this complication.
Answers are grounded in this paper and cite their sources.
Supports BP-DES as noninferior alternative to DP-DES for large-vessel stenting; challenges durable polymers as primary driver of very late stent thrombosis.
BACKGROUND: Biodegradable-polymer drug-eluting stents (BP-DES) were developed to be as effective as second-generation durable-polymer drug-eluting stents (DP-DES) and as safe >1 year as bare-metal stents (BMS). Thus, very late stent thrombosis (VLST) attributable to durable polymers should no longer appear. METHODS AND RESULTS: To address these early and late aspects, 2291 patients presenting with acute or stable coronary disease needing stents ≥3.0 mm in diameter between April 2010 and May 2012 were randomly assigned to biolimus-A9-eluting BP-DES, second-generation everolimus-eluting DP-DES, or thin-strut silicon-carbide-coated BMS in 8 European centers. All patients were treated with aspirin and risk-adjusted doses of prasugrel. The primary end point was combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization within 2 years. The combined secondary safety end point was a composite of VLST, myocardial infarction, and cardiac death. The cumulative incidence of the primary end point was 7.6% with BP-DES, 6.8% with DP-DES, and 12.7% with BMS. By intention-to-treat BP-DES were noninferior (predefined margin, 3.80%) compared with DP-DES (absolute risk difference, 0.78%; -1.93% to 3.50%; P for noninferiority 0.042; per protocol P=0.09) and superior to BMS (absolute risk difference, -5.16; -8.32 to -2.01; P=0.0011). The 3 stent groups did not differ in the combined safety end point, with no decrease in events >1 year, particularly VLST with BP-DES. CONCLUSIONS: In large vessel stenting, BP-DES appeared barely noninferior compared with DP-DES and more effective than thin-strut BMS, but without evidence for better safety nor lower VLST rates >1 year. Findings challenge the concept that durable polymers are key in VLST formation. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01166685.
No takes yet. Share an insight, caveat, or question.
Kaiser et al. (2014) conducted an RCT in Acute or stable coronary disease needing stents ≥3.0 mm in diameter (n=2,291). Biolimus-A9-eluting biodegradable-polymer drug-eluting stents (BP-DES) vs. Everolimus-eluting durable-polymer drug-eluting stents (DP-DES) and bare-metal stents (BMS) was evaluated on Combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization within 2 years (Absolute risk difference 0.78%, 95% CI -1.93 to 3.50, p=0.042 for noninferiority). Biolimus-A9-eluting BP-DES were noninferior to everolimus-eluting DP-DES for cardiac death, MI, and target-vessel revascularization at 2 years.
Synapse has enriched 10 related papers. Consider them for comparative context: