Key result
Biodegradable polymer DES was noninferior to durable polymer DES at 1 year in 2,603 patients with coronary artery disease, though 10-year results are truncated in the abstract.
Why the study?
Does a biodegradable polymer drug-eluting stent (Yukon Choice PC) improve long-term outcomes compared to durable polymer drug-eluting stents (Xience or Cypher) in patients with coronary artery disease?
Does a biodegradable polymer drug-eluting stent (Yukon Choice PC) improve long-term outcomes compared to durable polymer drug-eluting stents (Xience or Cypher) in patients with coronary artery disease?
Answers are grounded in this paper and cite their sources.
This editorial discusses the theoretical advantages and clinical evidence regarding biodegradable polymer drug-eluting stents compared to durable polymer stents, focusing on the 10-year outcomes of the ISAR-Test 4 trial.
Article, see p 325 D rug eluting stents (DES), the standard-of-care stents in contemporary percutaneous coronary intervention, significantly reduce the risk of restenosis in comparison with bare metal stents (BMS).However, first-generation durable polymer (DP) DES were associated with high rates of very late (>1 year) events such as restenosis, stent thrombosis, and neoatherosclerosis, events attributed to a persistent inflammation/hypersensitivity reaction to the polymer. 1 The solutions to this polymer-related problem proceeded in 3 directions: (1) development of more biocompatible DP that reduces inflammation and promotes faster healing; (2) development of biodegradable (BP) polymer that biodegrades after drug elution, leaving behind a BMS-like stent; and (3) development of polymer-free DES where the drug is delivered without a polymer and is therefore a BMS-like stent.The clinical gains from improvement in the polymer-related aspects of stent design have been apparent.The second-generation DP-DES have lower risk of restenosis, stent thrombosis, myocardial infarction (MI), and death in comparison with BMS or first-generation DP-DES. 2,3Despite these excellent results with the second-generation DP-DES, major adverse cardiovascular events continue to accrue beyond 1 year at a steady rate.This has been attributed to continued low-grade peri-strut inflammation and promotion of neoatherosclerosis with the second-generation DP-DES.As such, BP-DES were touted as the future of DES technology. 4linical trials of BP-DES showed lower restenosis and stent thrombosis in comparison with the first-generation DP-DES, although the results have been variable. 2However, the more important question has been the comparison of BP-DES with the second-generation DP-DES.Cumulative data from meta-analyses of randomized trials suggest, at best, the noninferiority of BP-DES in comparison with second-generation DP-DES. 5Given the short duration of these trials, many have posited that the benefits of BP-DES will be seen at longer duration of follow-up after the polymer fully biodegrades (over months to years depending on the polymer). 6he 10-year outcomes of the ISAR-Test 4 trial (Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents) in the current issue of Circulation 7 provide further insights into this question.The ISAR-Test 4 trial enrolled 2603 patients with coronary artery disease who were randomly assigned 2:1:1 to the Yukon Choice PC stent (a BP-DES coated on the abluminal surface of a stent [87 µm thick] with a unique microporous surface) versus the Xience stent (a second-generation DP-DES [81 µm thick]) versus the Cypher stent (a first-generation DP-DES [140 µm thick]).The trial showed noninferiority of the BP-DES in comparison with DP-DES at 1 year and concluded that "the results provide a framework for testing the potential clinical advantage of BP-DES over the medium to longterm." 6At 10 years follow-up, the second-generation DP-DES, and the BP-DES,
No takes yet. Share an insight, caveat, or question.
Sripal Bangalore (2019) conducted an editorial in coronary artery disease (n=2,603). Yukon Choice PC stent (biodegradable polymer DES) vs. Xience stent and Cypher stent (durable polymer DES) was evaluated. Biodegradable polymer DES was noninferior to durable polymer DES at 1 year in 2,603 patients with coronary artery disease, though 10-year results are truncated in the abstract.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: