Key result
Urgent TEE-guided trans-apical ViV successfully treats cardiogenic shock due to severe bioprosthetic degeneration.
Why the study?
Pre-operative CT scan provides essential procedural planning for ViV TAVI in degenerated aortic bioprostheses, but is not always feasible during acute presentations.
Can transoesophageal echocardiography safely guide an urgent transapical valve-in-valve procedure in a patient with cardiogenic shock when pre-operative CT is not feasible?
Case Report (n=1)
No
Can transoesophageal echocardiography safely guide an urgent transapical valve-in-valve procedure in a patient with cardiogenic shock when pre-operative CT is not feasible?
Transoesophageal echocardiography can serve as a crucial and effective alternative to CT scanning for guiding urgent transapical valve-in-valve procedures in hemodynamically unstable patients.
Answers are grounded in this paper and cite their sources.
May support TEE-guided urgent transapical valve-in-valve in shock without CT; leaves open need for prospective validation.
BACKGROUND: Transcatheter aortic valve implantation inside a previously implanted bioprosthesis is an alternative treatment for patients with degenerated surgical aortic bioprosthesis (AB) at high surgical risk. Pre-operative computed tomography (CT) scan provides essential information to the procedure planning, although in case of acute presentation it is not always feasible. CASE SUMMARY: A 32-year-old man with history of surgical treatment of aortic coarctation and Bio-Bentall procedure was transferred to our department in cardiogenic shock with a suspected diagnosis of acute myocarditis. A transthoracic echocardiogram (TTE) revealed a severely impaired biventricular function and AB degeneration causing severe stenosis. It was decided to undertake an urgent trans-apical valve-in-valve (ViV) procedure. Due to haemodynamic instability, a preoperative CT scan was not performed and transoesophageal echocardiography (TOE) was the main intraprocedural guiding imaging technique. Neither intraprocedural nor periprocedural complications occurred. Serial post-procedural TTE exams showed good functioning of the bioprosthesis and progressive improvement of left ventricular ejection fraction. Patient was discharged from the hospital 8 days after the intervention. DISCUSSION: A patient with cardiogenic shock due to severe degeneration of the AB was treated with urgent transapical ViV procedure. In this case, where urgent ViV technique was needed, TOE appeared to be a crucial alternative to CT scan and allowed us to perform a successful procedure.
No takes yet. Share an insight, caveat, or question.
Polizzi et al. (2021) conducted a case report in Cardiogenic shock due to severe degeneration of surgical aortic bioprosthesis (n=1). Transoesophageal echocardiography (TOE)-guided trans-apical valve-in-valve (ViV) procedure was evaluated on Procedural success and clinical recovery. An urgent transoesophageal echocardiography-guided trans-apical valve-in-valve procedure successfully treated a 32-year-old man presenting with cardiogenic shock due to severe bioprosthetic degeneration.
Synapse has enriched 10 related papers. Consider them for comparative context: