Key result
TEVAR raises ascending systolic pressure ~11 mmHg vs open arch replacement in ex vivo aortas.
Why the study?
Outcomes of therapeutic options for aortic arch pathologies needed evaluation comparing TEVAR with open arch replacement from a mechanical and biomechanical perspective.
Does TEVAR alter mechanical and biomechanical outcomes compared to open arch replacement in ex vivo perfused human thoracic aortas?
Does TEVAR alter mechanical and biomechanical outcomes compared to open arch replacement in ex vivo perfused human thoracic aortas?
TEVAR increases left ventricular afterload and alters wave dynamics compared to open arch replacement in an ex vivo human aorta model.
Answers are grounded in this paper and cite their sources.
May raise LV afterload after TEVAR versus open repair; hypothesis-generating for clinical outcomes.
This study aims to assess the outcomes of therapeutic options for aortic arch pathologies by comparing thoracic endovascular aortic repair (TEVAR) with open arch replacement (OAR) using woven polyester grafts from a mechanical and biomechanical perspective, with emphasis on ex vivo perfused human thoracic aortas reproducing heart rate and stroke volume conditions. Eleven non-diseased thoracic aortas from human cadavers were divided into TEVAR ( n = 5 ) and OAR ( n = 6 ) and tested using a custom-built mock circulation loop. Pressure, diameter, and stroke volume were monitored during perfusion before and after the intervention. Samples undergoing TEVAR showed a higher ascending systolic pressure post-intervention than OAR (TEVAR: 137 ± 9 mmHg vs OAR: 126 ± 6 mmHg, P = 0 . 017 ). After the intervention, a significant discrepancy in the mean pressure differences between the ascending and descending aorta Δ P was observed (TEVAR: 9 ± 3 mmHg vs OAR: 1 ± 2 mmHg, P = 0 . 004 ). Input impedance at zero frequency, approximating Windkessel resistance, was higher for TEVAR than for OAR (TEVAR: 1 . 78 ± 0 . 04 vs OAR: 1 . 66 ± 0 . 03 mmHg s/ml, P = 0 . 004 ). A correlation was found between the resistance and the negative peak of the time-normalized wave intensity analysis (Kendall’s coefficient τ = − 0 . 35 and P = 0 . 023 ). Another correlation was observed between resistance and Δ P ( τ = 0 . 51 , P = 0 . 001 ). Looking at the replication of heart rate and stroke volume over the course of the study, the observed differences can largely be attributed to the type of intervention. The results suggest that TEVAR has adverse effects compared to OAR, particularly with regard to left ventricular afterload. Clinicians should consider the possibility of increased afterload and altered wave dynamics when deciding on TEVAR, particularly in patients with pre-existing impaired cardiovascular conditions. • A unique comparative analysis of two predominant therapeutic interventions for aortic arch pathologies thoracic endovascular aortic repair (TEVAR) and open arch replacement (OAR) — is presented, with an emphasis on mechanical and biomechanical outcomes. • Perfused human thoracic aortas were used in a controlled mock circulation loop to reproduce heart rate and stroke volume to eliminate confounding factors and enable the evaluation of clinically feasible measures. • These insights are essential for clinicians and highlight the importance of considering biomechanical changes after intervention to compare patient outcomes. • Additionally, these findings are also valuable for graft development engineers, allowing them to investigate new grafts with clinically relevant measures before animal and human studies.
No takes yet. Share an insight, caveat, or question.
Yusefi et al. (2024) studied Aortic arch pathologies (n=11). Thoracic endovascular aortic repair (TEVAR) vs. Open arch replacement (OAR) was evaluated on Ascending systolic pressure post-intervention (p=0.017). TEVAR resulted in higher ascending systolic pressure post-intervention compared to open arch replacement in ex vivo perfused human thoracic aortas.
Synapse has enriched 10 related papers. Consider them for comparative context: