Why the study?
The haemodynamic performance and post-intervention complication risks of branched endografts used in thoracic endovascular aortic repair of the arch are not yet clear.
Does TEVAR with a single-branched endograft alter aortic haemodynamics and wall stress in a patient with an aortic arch aneurysm?
Does TEVAR with a single-branched endograft alter aortic haemodynamics and wall stress in a patient with an aortic arch aneurysm?
Patient-specific computational fluid dynamics and biomechanical analysis can identify high wall stress and displacement forces that may predict post-TEVAR complications such as device migration and endoleaks.
Patient-specific modeling of single-branched TEVAR reveals altered haemodynamics; leaves open translation to clinical outcomes or device selection.
Introduction: Thoracic endovascular aortic repair (TEVAR) of the arch is challenging given its complex geometry and the involvement of supra-aortic arteries. Different branched endografts have been designed for use in this region, but their haemodynamic performance and the risk for post-intervention complications are not yet clear. This study aims to examine aortic haemodynamics and biomechanical conditions following TVAR treatment of an aortic arch aneurysm with a two-component single-branched endograft. Methods: Computational fluid dynamics and finite element analysis were applied to a patient-specific case at different stages: pre-intervention, post-intervention and follow-up. Physiologically accurate boundary conditions were used based on available clinical information. Results: Computational results obtained from the post-intervention model confirmed technical success of the procedure in restoring normal flow to the arch. Simulations of the follow-up model, where boundary conditions were modified to reflect change in supra-aortic vessel perfusion observed on the follow-up scan, predicted normal flow patterns but high levels of wall stress (up to 1.3M MPa) and increased displacement forces in regions at risk of compromising device stability. This might have contributed to the suspected endoleaks or device migration identified at the final follow up. Discussion: Our study demonstrated that detailed haemodynamic and biomechanical analysis can help identify possible causes for post-TEVAR complications in a patient-specific setting. Further refinement and validation of the computational workflow will allow personalised assessment to aid in surgical planning and clinical decision making.
No takes yet. Share an insight, caveat, or question.
Sengupta et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: