Key result
Invasive pre-induction dynamic arterial elastance during deep breathing predicts post-induction hypotension with 0.78 AUC.
Why the study?
Dynamic arterial elastance has been suggested as a functional measure of arterial load, but whether pre-induction dynamic arterial elastance can predict post-induction hypotension required evaluation.
Does pre-induction dynamic arterial elastance predict post-induction hypotension in adult patients undergoing general anesthesia?
Observational (n=38)
Does pre-induction dynamic arterial elastance predict post-induction hypotension in adult patients undergoing general anesthesia?
Invasive pre-induction dynamic arterial elastance measured during deep breathing can predict post-induction hypotension in patients undergoing general anesthesia.
Answers are grounded in this paper and cite their sources.
Should not yet change practice; hypothesis-generating for invasive Eadyn in predicting post-induction hypotension.
STUDY OBJECTIVE: Dynamic arterial elastance (Eadyn) has been suggested as a functional measure of arterial load. We aimed to evaluate whether pre-induction Eadyn can predict post-induction hypotension. DESIGN: Prospective observational study. PATIENTS: Adult patients undergoing general anesthesia with invasive and non-invasive arterial pressure monitoring systems. MEASUREMENTS: We collected invasive and non-invasive Eadyns (n = 38 in each), respectively. In both invasive and non-invasive Eadyns, pre-induction Eadyns were obtained during one-minute tidal and deep breathing in each patient before anesthetic induction. Post-induction hypotension was defined as a decrease of >30% in mean blood pressure from the baseline value or any absolute mean blood pressure value of <65 mmHg for 10 min after anesthetic induction. The predictabilities of Eadyns for the development of post-induction hypotension were tested using receiver-operating characteristic curve analysis. MAIN RESULTS: Invasive Eadyn during deep breathing showed significant predictability with an area under the curve (AUC) of 0.78 (95% Confidence interval [CI], 0.61-0.90, P = 0.001). But non-invasive Eadyn during tidal breathing (AUC = 0.66, 95% CI, 0.49-0.81, P = 0.096) and deep breathing (AUC = 0.53, 95% CI, 0.36-0.70, P = 0.75), and invasive Eadyn during tidal breathing (AUC = 0.66, 95% CI, 0.41-0.74, P = 0.095) failed to predict post-induction hypotension. CONCLUSION: In our study, invasive pre-induction Eadyn during deep breathing -could predict post-induction hypotension. Despite its invasiveness, future studies will be needed to evaluate the usefulness of Eadyn as a predictor of post-induction hypotension because it is an adjustable parameter.
No takes yet. Share an insight, caveat, or question.
Oh et al. (2023) conducted an observational in Adult patients undergoing general anesthesia (n=38). Pre-induction dynamic arterial elastance (Eadyn) was evaluated on Post-induction hypotension (decrease of >30% in mean blood pressure from baseline or absolute mean blood pressure <65 mmHg) (AUC 0.78, 95% CI 0.61-0.90, p=0.001). Invasive pre-induction dynamic arterial elastance during deep breathing significantly predicted post-induction hypotension (AUC 0.78; 95% CI 0.61-0.90; P=0.001).
Synapse has enriched 10 related papers. Consider them for comparative context: