Key result
3D aortic root volume strongly correlates with 2D sinus of Valsalva dimensions.
Why the study?
Two-dimensional measurements are limited in representing the three-dimensional complexity of the aortic root, making volumetric measurement a potential alternative for more accurate assessment.
Does three-dimensional volumetric measurement correlate with standard two-dimensional measurements of the aortic root in individuals undergoing cardiac CT?
Observational (n=123)
Does three-dimensional volumetric measurement correlate with standard two-dimensional measurements of the aortic root in individuals undergoing cardiac CT?
Effect estimate: R2 = 0.8401
p-value: p=<0.0001
Three-dimensional volumetric measurement of the aortic root correlates strongly with two-dimensional bisecting measurements, providing reference data for structurally normal aortic roots.
2D bisecting measures may surrogate 3D aortic root volumetry on CT; leaves open validation in diseased valves.
Introduction Two‐dimensional measurements are self‐evidently limited when seeking accurately to represent the three‐dimensional complexity of the aortic root. Volumetric measurement, therefore, seems an ideal alternative for a more accurate assessment. Materials and Methods We retrospectively analyzed 123 individuals undergoing cardiac computed tomography. We measured the dimensions of the sinuses of Valsalva using routine multiplanar short axis imaging. Three conventional two‐dimensional methods were applied to measure the dimensions of the sinuses. These involved bisecting center of sinus‐to‐center of interleaflet triangle measures, along with center of sinus‐to‐center of sinus, and largest sinus‐to‐sinus measurements. We then quantified the volumes of the root using the volume‐rendering method. Results The mean dimensions of the sinuses were significantly greater when measured using the largest sinus‐to‐sinus method as opposed to center of sinus‐to‐center of interleaflet triangle and center of sinus‐to‐center of sinus methods (33.6 ± 3.6 mm vs. 31.1 ± 3.1 mm and 30.9 ± 3.3 mm, p < .0001). The mean root volume of 13.6 ± 4.2 ml showed the strongest correlation with the mean dimensions of the sinuses of Valsalva measured using the bisecting method ( R 2 = .8401, p < .0001). Conclusions By using two‐ and three‐dimensional measurements, we have provided average data for the structurally normal aortic root. The differences and correlations encountered should be noted when evaluating and following changes in the diseased root.
No takes yet. Share an insight, caveat, or question.
Suzuki et al. (2020) conducted an observational in Individuals undergoing cardiac computed tomography (n=123). Three-dimensional volumetric measurement vs. Two-dimensional measurements was evaluated on Correlation between 3D root volume and 2D dimensions of the sinuses of Valsalva (R2 = 0.8401, p=<0.0001). Three-dimensional volumetric measurement of the aortic root strongly correlated with two-dimensional bisecting center of sinus-to-center of interleaflet triangle measures (R2=0.8401, p<0.0001).