Answers are grounded in this paper and cite their sources.
The aim of this pilot study was to determine the safety and long-term efficacy of treating intrastent restenosis (ISR) with the slow-release sirolimus-eluting stent Bx Velocity (Cypher stent) without intravascular ultrasound (IVUS) guidance. Of patients who received a bare metal stent implantation and presented an ISR, 30-80% of the patients will develop a second restenosis within the stent, at the stent edges or both. To date, intravascular brachytherapy using beta- and gamma-radiation has been the only effective treatment for ISR. Twenty-three patients with ISR and evidence of ischemia were treated with Cypher stent. Clinical information was collected 1, 8, 12, and 24 months after stent implantation. During the first 8 months of the study, in-stent lumen diameter remained essentially unchanged from postprocedure in 80% of the case. The target lesion repeat revascularization (TLR) was 17%, of which 50% were oculostenotic reflexes. Only one patient presented a restenosis greater than 70%. During the 2-year study period, the TLR rate was 17%; the major adverse coronary event rate was 26%, and the non-Q-wave myocardial infarction (MI) rate was 9%. There were no reports of death, coronary artery bypass grafting, or Q-wave MI during the study. This study demonstrates the feasibility of using sirolimus-eluting stents without IVUS guidance for the treatment of ISR, providing long-term stability of immediate results.
No takes yet. Share an insight, caveat, or question.
Commeau et al. (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: