Answers are grounded in this paper and cite their sources.
Phase current reconstruction (PCR) strategy can improve the fault tolerance of permanent magnet synchronous motor (PMSM) drives. The PCR precision is largely affected by the unmeasurable zones and time-sharing sampling errors. The upper limit ( T limit ) of PCR allowable range can reflect the requirement of different PCR methods for the minimum sampling time ( T min ). With a longer T limit , there is sufficient time for sampling, even if T limit is halved due to the symmetrical waveform. Therefore, the extension of T limit is the key to eliminate the unmeasurable zones and time-sharing sampling errors. In this article, a method to increase T limit is proposed, which introduces the suitable auxiliary vectors in different regions to extend the duration time of the sampling vectors. With the help of a longer T limit (12.5% T s ), it is possible to eliminate all the unmeasurable zones and time-sharing sampling errors, relieve the pressure on the hardware of current loop, improve the sampling accuracy, and facilitate the reliable operation of the drive. Besides, the switching action times of IGBTs can be reduced by about one-third in the high modulation area. The proposed method is finally proved to accurately reconstruct the phase currents by the experimental results on the PMSM prototype.
No takes yet. Share an insight, caveat, or question.
Song et al. (2022) studied this question.