Key result
Cuff inflations during 24-hour ambulatory monitoring show no impact on asleep SBP versus cuffless monitoring.
Why the study?
The influence of cuff inflations on nighttime measurements during 24h ambulatory BP measurements is unknown.
Does cuff inflation during 24h ambulatory BP monitoring affect asleep blood pressure and sleep parameters in adult individuals?
Observational (n=21)
Does cuff inflation during 24h ambulatory BP monitoring affect asleep blood pressure and sleep parameters in adult individuals?
Cuff inflations during 24-hour ambulatory blood pressure monitoring do not significantly impact asleep blood pressure, sleep efficiency, or desaturations.
Answers are grounded in this paper and cite their sources.
May reassure on asleep BP accuracy with cuff ABPM; leaves open sleep quality effects in larger cohorts.
The influence of cuff inflations on nighttime measurements during 24h ambulatory blood pressure (BP) measurements is unknown. We investigated the potential effect of cuff-inflations on asleep parameters using measurements taken simultaneously with a cuffless device using pulse-transit-time (PTT). On the first day of measurement, standard cuff-based 24h BP and cuf-fless measurements were simultaneously performed on right and left arms (CUFF/PTT-D). 1-2 days after the first measurement, the cuffless device was worn alone (PTT-D). Only data from the cuffless device was analyzed. The following mean asleep parameters were analyzed: systolic and diastolic BP, arousals, sleep efficiency, total arousals, arousal per hour and desaturations. 21 in-dividuals were prospectively enrolled. Mean (SD) age was 47(±15) years and 57% were female. Mean systolic asleep BP for the during CUFF/PTT-D and during PTT-D were 131(±21) and 131(±26) mmHg respectively. Mean diastolic asleep BP values during CUFF/PTT-D and during PTT-D were 80(±14) and 84(±14) mmHg respectively (p=0.860, p=0.100 respectively). Systolic and diastolic asleep mean difference was 0.1 (±18.0) and -3.6 (±9.8) mmHg, respectively. There were significantly more total arousals during PTT-D (p=0.042). There was no significant difference seen in sleep efficiency (p=0.339) or desaturations (p=0.896) between the two measurements. We could not show any significant impact from cuff inflations during asleep PTT-D measurements.
No takes yet. Share an insight, caveat, or question.
Socrates et al. (2023) reported an observational. Cuff-based 24h ambulatory blood pressure measurement vs. Cuffless measurement alone was evaluated on Mean systolic asleep blood pressure (Mean difference 0.1 mmHg, p=0.860). Cuff inflations during 24-hour ambulatory monitoring did not significantly impact mean asleep systolic blood pressure compared to cuffless monitoring alone (131 vs 131 mmHg; p=0.860).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: