Key result
Excessive oversizing in mitral ViV predicts THV deformation and ~27% 30-day HALT incidence.
Why the study?
Oversizing in mitral valve-in-valve procedures can cause non-uniform transcatheter heart valve expansion with potential implications for durability, but the extent and predictors of deformation were unclear.
Does the degree of oversizing in mitral valve-in-valve procedures affect transcatheter heart valve deformation and hypoattenuating leaflet thickening?
Observational (n=33)
Does the degree of oversizing in mitral valve-in-valve procedures affect transcatheter heart valve deformation and hypoattenuating leaflet thickening?
Excessive oversizing during mitral valve-in-valve procedures leads to transcatheter heart valve deformation and underexpansion, which may increase the risk of hypoattenuating leaflet thickening.
Excessive oversizing was associated with THV deformation and HALT after mitral ViV; hypothesis-generating for optimized sizing strategies.
BACKGROUND: The use of oversizing in mitral valve-in-valve (MViV) procedures can lead to non-uniform expansion of transcatheter heart valves (THV). This may have implications for THV durability. AIMS: The objective of this study was to assess the extent and predictors of THV deformation in MViV procedures. METHODS: We examined 33 patients who underwent MViV with SAPIEN prostheses. The extent of THV deformation (deformation index, eccentricity, neosinus volume, asymmetric leaflet expansion and vertical deformation) and hypoattenuating leaflet thickening (HALT) were assessed using cardiac computed tomography (CT), performed prospectively at 30 days post-procedure. For descriptive purposes, the THV deformation index was calculated, with values >1.00 representing a more hourglass shape. RESULTS: Non-uniform underexpansion of THV was common after MViV implantation, with a median expansion area of 74.0% (interquartile range 68.1-84.1) at the narrowest level and a THV deformation index of 1.21 (1.13-1.29), but circularity was maintained with eccentricity ranging from 0.24 to 0.28. The degree of oversizing was a key factor associated with greater underexpansion and a higher deformation index (β=-0.634; p<0.001; β=0.594; p<0.001, respectively). Overall, the incidence of HALT on the 30-day postprocedural CT was 27.3% (9 of 33). Most patients (32 of 33) were on anticoagulation therapy, but the prothrombin time and international normalised ratio (PT-INR) at the time of the CT scan was <2.5 in 23 of 32 patients. Among patients with a PT-INR of <2.5, HALT was predominantly observed with a high THV deformation index of ≥1.18. CONCLUSIONS: THV deformation, i.e., underexpansion and an hourglass shape, commonly occurs after MViV implantation and is negatively affected by excessive oversizing. Optimising THV expansion during MViV could potentially prevent HALT.
No takes yet. Share an insight, caveat, or question.
Fukui et al. (2023) conducted an observational in Mitral valve-in-valve (MViV) (n=33). Mitral valve-in-valve with SAPIEN prostheses was evaluated on Extent of THV deformation and hypoattenuating leaflet thickening (HALT). Transcatheter heart valve deformation commonly occurred after mitral valve-in-valve implantation, with excessive oversizing predicting greater deformation and a 27.3% incidence of HALT at 30 days.