Key result
Balloon-expandable TAVI valves caused a significantly larger reduction in mitral valve anterior to posterior diameter compared to self-expandable valves (-0.25 cm vs -0.11 cm; P<.05).
Why the study?
The study was conducted to evaluate the impact of TAVI on mitral valve geometry and function.
Does transcatheter aortic valve implantation (TAVI) alter mitral valve geometry and function in patients undergoing the procedure?
Observational (n=84)
Does transcatheter aortic valve implantation (TAVI) alter mitral valve geometry and function in patients undergoing the procedure?
Absolute Event Rate: -0.25% vs -0.11%
p-value: p=< .05
TAVI acutely alters mitral valve geometry by reducing annular and tenting areas, with balloon-expandable valves causing more pronounced changes than self-expandable valves.
Valve selection in TAVI may warrant mitral geometry consideration; leaves open effects on regurgitation or outcomes.
Background The aim of this study was to evaluate the impact of transcatheter aortic valve implantation (TAVI) on mitral valve geometry and function. Methods Eighty-four patients underwent TAVI. Forty-four (52%) patients received a balloon-expandable valve and 40 (48%) were implanted with a self-expandable valve. All patients underwent three-dimensional-volumetric transesophageal echocardiography of the mitral valve before and immediately after TAVI. A dedicated software was used for assisted semiautomatic measurement of mitral annular geometry. Results During systole, the anterior to posterior (AP) diameter was significantly reduced after the procedure (3.4 ± 0.5 cm vs 3.2 ± 0.5 cm; P < .05). The mitral annular area (10.8 ± 2.8cm2 vs 9.9 ± 2.6cm2; P < .05) as well as the tenting area (1.6 ± 0.7 cm2 vs 1.2 ± 0.6 cm2; P < .001) measured at mid-systole were reduced after TAVI. Diastolic measures were similar. Patients treated with balloon-expandable valves showed a significantly larger reduction in the AP diameter compared to self-expandable valves (−0.25 cm vs −0.11 cm; P < .05). The reduction of the annular area was higher in the balloon-expandable group (−1.2 ± 1.59 vs −0.22 ± 1.41; P < .05). Grade of mitral regurgitation did improve or remained stable after TAVI. Conclusion TAVI significantly impacts the mitral valve and mitral annular geometry and morphology. The choice of the prosthesis (balloon- vs self-expandable) may be relevant for those changes.
No takes yet. Share an insight, caveat, or question.
Meyer et al. (2020) conducted an observational in Patients undergoing TAVI (n=84). Balloon-expandable valve vs. Self-expandable valve was evaluated on Reduction in anterior to posterior (AP) diameter during systole (p=< .05). Balloon-expandable TAVI valves caused a significantly larger reduction in mitral valve anterior to posterior diameter compared to self-expandable valves (-0.25 cm vs -0.11 cm; P<.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: