Key result
TAVR acutely improves MR in ~54% of patients, driven by decreased mitral leaflet tenting.
Why the study?
The effect of TAVR on the mitral valve apparatus and factors influencing mitral regurgitation reduction with or without mitral leaflet tethering after TAVR are poorly understood.
Does TAVR improve mitral regurgitation and mitral valve apparatus structure in patients undergoing the procedure?
Cohort (n=90)
Does TAVR improve mitral regurgitation and mitral valve apparatus structure in patients undergoing the procedure?
Answers are grounded in this paper and cite their sources.
TAVR acutely improves mitral regurgitation, which is predominantly related to changes in global left ventricular hemodynamics and mitral leaflet tethering rather than mitral annular geometry.
BACKGROUND: The effect of transcatheter aortic valve replacement (TAVR) on the mitral valve apparatus and factors influencing the reduction of mitral regurgitation with or without mitral leaflet tethering after TAVR are poorly understood. The present 3-dimensional (3D) transesophageal echocardiography study aimed to elucidate early changes further in the structure and function of the mitral valve apparatus after TAVR. METHODS AND RESULTS: We analyzed 90 patients (nontenting group, 56 patients and tenting group, 34 patients) who underwent TAVR using the Edwards SAPIEN and had intraprocedural 3D transesophageal echocardiography evaluation of the mitral valve. Of all patients, mitral regurgitation improved in 54%, remained the same in 38%, and worsened in 8% 1 day after TAVR. There were no statistically significant differences in mitral annular 3D parameters before and after TAVR in both groups. In the tenting group, tenting area (P<0.01) and tenting height (P<0.01) were decreased, and coaptation length was increased (P<0.05) after TAVR. In a multivariable analysis, the predictors of improved mitral regurgitation were the decrease of tenting area (odds ratio, 8.15; 95% confidence interval, 1.31-50.7; P<0.05) and the decrease of valvuloarterial impedance (odds ratio, 7.57; 95% confidence interval, 1.15-49.9; P<0.05) in the tenting group and the decrease of valvuloarterial impedance (odds ratio, 6.96; 95% confidence interval, 1.24-39.2; P<0.05) in the nontenting group. CONCLUSIONS: Mitral leaflet tethering was improved immediately by TAVR in patients with mitral leaflet tenting regardless of mitral annular geometry. Acute improvement in mitral regurgitation after TAVR is predominantly related to global left ventricular hemodynamics and mitral leaflet tethering change.
No takes yet. Share an insight, caveat, or question.
Shibayama et al. (2014) conducted a cohort in Mitral regurgitation in patients undergoing TAVR (n=90). Transcatheter aortic valve replacement (TAVR) vs. Pre-TAVR baseline was evaluated on Improved mitral regurgitation 1 day after TAVR (OR 8.15, 95% CI 1.31-50.7, p=<0.05). TAVR acutely improved mitral regurgitation in 54% of patients, which was strongly predicted by a decrease in tenting area among those with mitral leaflet tenting.
Synapse has enriched 10 related papers. Consider them for comparative context: