Key result
Transcatheter aortic valve implantation reduced mitral regurgitation severity, with effective regurgitant orifice area decreasing from 24.4 to 11.2 mm2.
Why the study?
Does TAVI improve mitral regurgitation severity in patients with baseline MR ≥ 2+?
Cohort (n=35)
Does TAVI improve mitral regurgitation severity in patients with baseline MR ≥ 2+?
Answers are grounded in this paper and cite their sources.
TAVI significantly improves mitral regurgitation severity in patients with baseline MR ≥ 2+, with subgroup analysis suggesting this may be related to the type of valve implanted.
OBJECTIVE: This study aims to assess changes in mitral regurgitation (MR) severity after transcatheter aortic valve implantation (TAVI). BACKGROUND: Existing data on MR after TAVI are contradictory. METHODS: Thirty-five patients with MR graded ≥ 2+ were followed after undergoing TAVI with either the Edwards Sapien or CoreValve device. Echocardiography was performed the week before and 3 months after the procedure. MR was graded on a scale of 0 to 4+, classified as organic or functional, and the effective regurgitant orifice area (EROA) and MR index were calculated. RESULTS: At baseline, MR was graded 4+ in 4 (11.4%) patients, 3+ in 10 (28.6%), and 2+ in 21 (60%). At follow-up, MR was graded at 3+ in 4 (11.4%) patients, 2+ in 8 (22.9%), and 1+ in 19 (54.3%); 4 (11.4%) exhibited no MR. EROA (24.4 ± 11.5 mm(2) pre-TAVI vs. 11.2 ± 10.3 mm(2) post-TAVI, P < 0.001) and MR index (1.9 ± 0.3 pre-TAVI vs. 1.3 ± 0.7 post-TAVI, P < 0.001) were reduced with TAVI, independent of the etiology. MR decreased by at least 1 grade in 28 (80%) patients, with a reduction ≥2 grades in 10 (28.6%) patients; no patient showed a worsened condition. Subgroup analyses showed that the reduction in MR was significant in patients treated with the Edwards Sapien device but not in patients treated with the CoreValve device. CONCLUSIONS: This multiparametric echocardiographic evaluation showed that MR improved significantly after TAVI and that this result may be related to the type of valve implanted.
No takes yet. Share an insight, caveat, or question.
Giordana et al. (2012) conducted a cohort in Mitral Regurgitation (n=35). Transcatheter aortic valve implantation (TAVI) vs. Baseline (pre-TAVI) was evaluated on Effective regurgitant orifice area (EROA) in mm2 (p=<0.001). Transcatheter aortic valve implantation reduced mitral regurgitation severity, with effective regurgitant orifice area decreasing from 24.4 to 11.2 mm2.
Synapse has enriched 10 related papers. Consider them for comparative context: