Key result
In patients with MR-conditional CIEDs, the rate of MR scans performed among referred patients was higher in pacemaker subjects compared to ICD subjects.
Observational (n=555)
Despite having MR-conditional systems, a significant proportion of CIED patients, particularly those with ICDs, are denied access to MRI scans.
Answers are grounded in this paper and cite their sources.
MRI access remains restricted for MR-conditional ICD patients; leaves open whether referral practices or device factors drive disparities.
Aims: The Really ProMRI study evaluates magnetic resonance imaging (MRI) access for patients with cardiac implantable electronic devices (CIEDs) as well as the performance of magnetic resonance (MR)-conditional leads when undergoing MRI. Methods and results: Patients either with an MR-conditional pacemaker or implantable defibrillator (ICD) system or with at least a component (device or one or more leads) from an MR-conditional system, were asked to fill in a questionnaire when they were referred to a MR scan. The rate of prescription, denial, or execution of MR examinations was evaluated in a 1-year follow-up visit. In total, 555 patients [median age (interquartile range) 72.2 (62.2-78.6); 72% male] were enrolled, 49% (270) with a pacemaker, 51% (285) with an ICD system. Five-hundred and ten patients completed the follow-up period. A total of 37 MRI referrals were reported in 35 patients, with a consequent event rate of 7.0/100 patient-years (CI, 4.9-9.7). Fourteen were denied, while 23 [66%; (CI, 48-81%)] were performed. The number of patients with MR referrals was not statistically different between pacemaker and ICD groups (21 vs. 14; P = 0.178). The rate of scans performed was higher in the pacemaker subjects (19/23 vs. 4/14, P = 0.003), while it was similar between patients with or without a complete MR-conditional system (19/30 vs. 4/7, P = 0.606). Conclusion: In this study, we reported a 7.0/100 patient-year's event rate of MR prescriptions in CIED patients. Many examinations were denied, despite MR-conditional systems, especially in ICD patients. Regulatory and cultural changes are needed to allow wider access to MR imaging in CIED patients with MR-conditional systems.
No takes yet. Share an insight, caveat, or question.
Celentano et al. (2017) conducted an observational in Patients with MR-conditional pacemaker or ICD systems (n=555). MR-conditional pacemaker vs. MR-conditional ICD was evaluated on Execution of MR examinations among referred patients (p=0.003). In patients with MR-conditional CIEDs, the rate of MR scans performed among referred patients was higher in pacemaker subjects compared to ICD subjects.
Synapse has enriched 10 related papers. Consider them for comparative context: