Key result
The Polar Precision Prime PPG system demonstrated excellent reliability and low systematic bias (<1 bpm) compared to the Polar H10 chest strap during an interval running protocol.
Why the study?
PPG heart rate devices are affected by motion artifacts during running, questioning their accuracy in training load systems despite recent technological improvements.
Does the Polar Precision Prime PPG system accurately measure heart rate compared to the Polar H10 chest strap in long distance runners during interval training?
Observational (n=37)
Does the Polar Precision Prime PPG system accurately measure heart rate compared to the Polar H10 chest strap in long distance runners during interval training?
The new Polar Precision Prime PPG system provides accurate heart rate monitoring during high-intensity interval running compared to a reference chest strap.
Answers are grounded in this paper and cite their sources.
May support PPG HR monitoring in interval running; leaves open prospective validation in diverse athletes.
Photoplethysmography (PPG) heart rate devices are greatly affected by the motion artifacts of running. As a result, their application in training load systems and effort control strategies based on heart rate (HR) could be debatable. In 2019, Polar applied some new features on their PPG devices to improve their accuracy. Thus, the purpose of this study was to determine the level of agreement between the new PPG system Polar Precision Prime™ and the chest strap Polar H10 (reference system) in the HR monitoring during an interval running protocol. A group of 37 long distance runners completed an interval running protocol of 10 min composed of five 1-min trials with an active break of 1-min between each trial. An excellent reliability (ICC > 0.9) was obtained for the entire interval running protocol with the lowest values in the first 2 min (ICC = 0.960–0.949), slight differences between intensities (ICC = 0.992–0.986), and a reduction of the observed tendency (ICC > 0.9) when the Edwards quantification model was applied (ICC = 0.877–0.967). The Bland-Altman plots with the final HR values of each trial establish a systematic bias (<1 bpm) for all intervals with a random error (<4 bpm), except in the first trial which had a higher random error (6.85 bpm). In conclusion, the innovations applied in the new PPG system provide the accuracy required for use in diverse functions, including endurance running.
No takes yet. Share an insight, caveat, or question.
Ruiz‐Alias et al. (2021) conducted an observational in endurance running (n=37). Polar Precision Prime™ PPG system vs. Polar H10 chest strap was evaluated on level of agreement in HR monitoring (ICC > 0.9). The Polar Precision Prime PPG system demonstrated excellent reliability and low systematic bias (<1 bpm) compared to the Polar H10 chest strap during an interval running protocol.