Key result
Overlapping paclitaxel-eluting stents in a porcine model reduced late lumen loss but caused marked intramural thrombi compared to bare-metal stents.
Why the study?
Does overlapping paclitaxel-eluting stent implantation compared to bare-metal stents affect angioscopic and histopathologic outcomes in pig coronary arteries at 1 month?
Does overlapping paclitaxel-eluting stent implantation compared to bare-metal stents affect angioscopic and histopathologic outcomes in pig coronary arteries at 1 month?
In a porcine model, overlapping paclitaxel-eluting stents reduce neointimal thickness but are associated with marked intramural thrombi and impaired adjacent endothelial function compared to bare-metal stents at 1 month.
Answers are grounded in this paper and cite their sources.
May increase intramural thrombosis risk with overlapping paclitaxel-eluting stents; leaves open human applicability and need for clinical trials.
BACKGROUND: Systematic analysis of in vivo angioscopy and postmortem histopathology for paclitaxel-eluting stents (PES) has not been previously reported. We assessed 1-month angioscopic and histopathologic sequelae of overlapping PES in pig coronary arteries. METHODS AND RESULTS: Overlapping PES and bare-metal stents (BMS; n=9, one pair per pig) were implanted, and animals were euthanized at 1 month. Late lumen loss was reduced in PES compared with BMS (0.46+/-0.63 mm versus 1.30+/-0.50 mm; P=0.01). Angioscopically, PES stent struts were clearly visible and accompanied by substantial red material indicating mural thrombi. In contrast, stent struts and mural thrombi were barely visible in BMS (P<0.001 versus PES). Macroscopically, mural thrombi were abundant but distributed irregularly throughout the PES, with greater concentration in overlapping segments. Only occasional mural thrombi were noted for BMS. Microscopically, neointima of BMS was fibrocellular and mature, whereas only a thin layer of immature neointima was seen in PES. Neointimal thickness was less in PES than BMS (0.11+/-0.07 mm versus 0.33+/-0.12 mm; P=0.018). Additionally, extensive para-strut and intramural thrombi, red blood cell debris, and minute luminal thrombi were observed in PES. Despite normal angioscopic appearance of both proximal and distal nonstented reference segments, endothelium-dependent relaxation to substance P was notably diminished (PES, 0+/-7% versus BMS, 10+/-6%; P=0.007), whereas nitroglycerin response was preserved (PES, 9+/-5% versus BMS, 12+/-7%; P=0.34). CONCLUSIONS: In the porcine coronary model, overlapping PES is associated with marked intramural thrombi, which was accurately detected on angioscopy at 1 month. Moreover, despite normal luminal angioscopic appearance, adjacent nonstented reference segments demonstrated impaired endothelium-dependent vasoreactivity.
No takes yet. Share an insight, caveat, or question.
Shinke et al. (2008) studied Coronary stenting (porcine model) (n=9). Overlapping paclitaxel-eluting stents (PES) vs. Bare-metal stents (BMS) was evaluated on Late lumen loss (p=0.01). Overlapping paclitaxel-eluting stents in a porcine model reduced late lumen loss but caused marked intramural thrombi compared to bare-metal stents.
Synapse has enriched 10 related papers. Consider them for comparative context: