Key result
Artificial neural network model cuts cardiac force generation variables by ~99% with minimal error.
The proposed 3D-0D coupled electromechanical model of the human heart successfully maintains energy conservation, offering a new computational tool for validating heart energy usage.
Accelerates cardiac electromechanical simulations; leaves open clinical validation and patient-specific integration.
We propose an integrated electromechanical model of the human heart, with focus on the left ventricle, wherein biophysically detailed models describe the different physical phenomena concurring to the cardiac function. We model the subcellular generation of active force by means of an Artificial Neural Network, which is trained by a suitable Machine Learning algorithm from a collection of pre-computed numerical simulations of a biophysically detailed, yet computational demanding, high-fidelity model. To provide physiologically meaningful results, we couple the 3D electromechanical model with a closed-loop 0D (lumped parameters) model describing the blood circulation in the whole cardiovascular network. We prove that the 3D-0D coupling of the two models is compliant with the principle of energy conservation, which is achieved in virtue of energy-consistent boundary conditions that account for the interaction among cardiac chambers within the computational domain, pericardium and surrounding tissue. We thus derive an overall balance of mechanical energy for the 3D-0D model. This provides a quantitative insight into the energy utilization, dissipation and transfer among the different compartments of the cardiovascular network and during different stages of the heartbeat. In virtue of this new model and the energy balance, we propose a new validation tool of heart energy usage against relationships used in the daily clinical practice. Finally, we provide a mathematical formulation of an inverse problem aimed at recovering the reference configuration of one or multiple cardiac chambers, starting from the stressed configuration acquired from medical imaging. This is fundamental to correctly initialize electromechanical simulations. Numerical methods and simulations of the 3D-0D model will be detailed in Part II.
No takes yet. Share an insight, caveat, or question.
Regazzoni et al. (2020) studied Cardiac electromechanics. Artificial Neural Network-based surrogate model vs. High-fidelity RDQ18 model was evaluated. An Artificial Neural Network-based surrogate model reduced the number of internal variables for cardiac force generation from over 2000 to 2 with an overall relative error of 10^-3.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: