Key result
Time-varying spectral analysis of heart-rate variability accurately determined the second ventilatory threshold compared to gas-exchange (mean difference 0.1 beats/min; r2=0.903).
Why the study?
Does spectral analysis of heart-rate variability accurately determine the second ventilatory threshold compared to the gas-exchange method during upper body exercise in ski mountaineers?
Observational (n=16)
Does spectral analysis of heart-rate variability accurately determine the second ventilatory threshold compared to the gas-exchange method during upper body exercise in ski mountaineers?
Effect estimate: r2 0.903
A specific time-varying spectral analysis of heart-rate variability can accurately determine the second ventilatory threshold during incremental upper body exercise.
May support non-invasive VT2 detection in athletes; hypothesis-generating and should not yet change practice.
To determine the most accurate method based on spectral analysis of heart-rate variability (SA-HRV) during an incremental and continuous maximal test involving the upper body, the authors tested 4 different methods to obtain the heart rate (HR) at the second ventilatory threshold (VT(2)). Sixteen ski mountaineers (mean ± SD; age 25 ± 3 y, height 177 ± 8 cm, mass 69 ± 10 kg) performed a roller-ski test on a treadmill. Respiratory variables and HR were continuously recorded, and the 4 SA-HRV methods were compared with the gas-exchange method through Bland and Altman analyses. The best method was the one based on a time-varying spectral analysis with high frequency ranging from 0.15 Hz to a cutoff point relative to the individual's respiratory sinus arrhythmia. The HR values were significantly correlated (r(2) = .903), with a mean HR difference with the respiratory method of 0.1 ± 3.0 beats/min and low limits of agreements (around -6 /+6 beats/min). The 3 other methods led to larger errors and lower agreements (up to 5 beats/min and around -23/+20 beats/min). It is possible to accurately determine VT(2) with an HR monitor during an incremental test involving the upper body if the appropriate HRV method is used.
No takes yet. Share an insight, caveat, or question.
Mourot et al. (2014) conducted an observational in Ski mountaineers (n=16). Spectral analysis of heart-rate variability (SA-HRV) vs. Gas-exchange method was evaluated on Heart rate at the second ventilatory threshold (VT2) (r2 0.903). Time-varying spectral analysis of heart-rate variability accurately determined the second ventilatory threshold compared to gas-exchange (mean difference 0.1 beats/min; r2=0.903).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: