Key result
Heart rate and heart rate variability metrics accurately reflected anaerobic threshold during a discontinuous cycle test, with differences between metric threshold and AT of less than 14 W.
Why the study?
Do heart rate and heart rate variability responses reflect anaerobic threshold in cyclists?
Cross-Sectional (n=15)
Do heart rate and heart rate variability responses reflect anaerobic threshold in cyclists?
Answers are grounded in this paper and cite their sources.
Heart rate and heart rate variability metrics accurately reflect anaerobic threshold during a discontinuous cycle test, providing a potential alternative to ventilatory threshold measurement.
International Journal of Exercise Science 7(1) : 45-53, 2014. The purpose was to determine if heart rate (HR) and heart rate variability (HRV) responses would reflect anaerobic threshold (AT) using a discontinuous, incremental, cycle test. AT was determined by ventilatory threshold (VT). Cyclists (30.6±5.9y; 7 males, 8 females) completed a discontinuous cycle test consisting of 7 stages (6 min each with 3 min of rest between). Three stages were performed at power outputs (W) below those corresponding to a previously established AT, one at W corresponding to AT, and 3 at W above those corresponding to AT. The W at the intersection of the trend lines was considered each metric’s “threshold”. The averaged stage data for Ve, HR, and time- and frequency-domain HRV metrics were plotted versus W. The W at the “threshold” for the metrics of interest were compared using correlation analysis and paired-sample t-test. In all, several heart rate-related parameters accurately reflected AT with significant correlations (p≤0.05) were observed between AT W and HR, mean RR interval (MRR), low and high frequency spectral energy (LF and HR, respectively), high frequency peak (fHF), and HFxfHF metrics’ threshold W (i.e., MRRTW, etc.). Differences in HR or HRV metric threshold W and AT for all subjects were less than 14 W. The steady state data from discontinuous protocols may allow for a true indication of steady-state physiologic stress responses and corresponding W at AT, compared to continuous protocols using 1-2 min exercise stages.
No takes yet. Share an insight, caveat, or question.
Park et al. (2014) conducted a cross-sectional in Healthy cyclists (n=15). Discontinuous, incremental cycle test vs. Ventilatory threshold (VT) was evaluated on Anaerobic threshold (AT) determined by HR and HRV metrics compared to ventilatory threshold (VT) (p=≤0.05). Heart rate and heart rate variability metrics accurately reflected anaerobic threshold during a discontinuous cycle test, with differences between metric threshold and AT of less than 14 W.
Synapse has enriched 10 related papers. Consider them for comparative context: