Key result
Trans-thoracic conductance showed a strong relationship with intra-thoracic impedance and BNP levels, suggesting it may noninvasively indicate pulmonary congestion in heart failure patients.
Why the study?
Does trans-thoracic conductance correlate with intra-thoracic impedance in patients with chronic heart failure?
Observational (n=70)
Does trans-thoracic conductance correlate with intra-thoracic impedance in patients with chronic heart failure?
Trans-thoracic conductance strongly correlates with intra-thoracic impedance and BNP levels, suggesting it may be a useful noninvasive marker for pulmonary congestion in heart failure patients without implanted devices.
AIMS: In chronic heart failure, changes of intra-thoracic impedance (Z0IT) may suggest impending pulmonary congestion; a similar result has been found by measuring trans-thoracic conductance (TFCTT = 1/Z0 = 1/kΩ). We assumed that a relationship could exist between Z0IT and TFCTT. METHODS: We collected 140 measurements from 70 patients carrying an implantable cardioverter-defibrillator/cardiac resynchronization device with the CareLink function (71 ± 9 years, New York Heart Association (NYHA) 2.4 ± 0.9, ejection fraction 31 ± 8%, optimal treatment); they were studied during system alarms and after appropriate treatment (diuretics and/or vasodilators, n = 42) or during clinical stability and at the time of a system alarm (n = 28); correspondent BNP values were obtained. We related Z0IT obtained by the device, with TFCTT obtained with a commercial system. RESULTS: A strong relationship was found between Z0IT and TFCTT. Changes in the variables after treatment or during worsening conditions were of the same direction and order of magnitude, and were related to BNP levels obtained simultaneously. CONCLUSIONS: Trans-thoracic conductance, similarly to intra-thoracic impedance, may noninvasively point to pulmonary congestion and be useful in patients not carrying an implanted device. The possibility of remotely obtaining this variable should be evaluated for the telemonitoring of heart failure patients.
No takes yet. Share an insight, caveat, or question.
Malfatto et al. (2014) conducted an observational in chronic heart failure (n=70). Trans-thoracic conductance and intra-thoracic impedance measurement was evaluated on Relationship between intra-thoracic impedance (Z0IT) and trans-thoracic conductance (TFCTT). Trans-thoracic conductance showed a strong relationship with intra-thoracic impedance and BNP levels, suggesting it may noninvasively indicate pulmonary congestion in heart failure patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: