Key result
Internet-based remote monitoring of intrathoracic impedance trends is feasible, with 94% of patients crossing the fluid index threshold showing evidence of clinically relevant events.
Why the study?
Is Internet-based remote monitoring of intrathoracic impedance feasible and what is the resource utilization in a heart failure disease management program?
Observational
Is Internet-based remote monitoring of intrathoracic impedance feasible and what is the resource utilization in a heart failure disease management program?
Internet-based remote monitoring of intrathoracic impedance trends is feasible as part of daily HF disease management and effectively identifies clinically relevant events with manageable resource utilization.
Answers are grounded in this paper and cite their sources.
Supports remote impedance monitoring feasibility in HF programs; leaves open outcome impact in prospective trials.
Changes in intrathoracic impedance (Z) leading to crossing of a derived fluid index (FI) threshold has been associated with heart failure (HF) hospitalization. The authors developed a remote monitoring program as part of HF disease management and prospectively examined the feasibility and resource utilization of monitoring individuals with an implanted device capable of measuring Z. An HF nurse analyzed all transmitted data daily, as they were routinely uploaded as part of quarterly remote device monitoring, and called the patient if the FI crossed the threshold (arbitrarily defined at 60 Omega) to identify clinically relevant events (CREs) that occurred during this period (eg, worsening dyspnea or increase in edema or weight). A total of 400 uploads were completed during the 4-month study period. During this period, 34 patients (18%) had an FI threshold crossing, averaging 0.52 FI threshold crossings per patient-year. Thirty-two of 34 patients contacted by telephone (94%) with FI threshold crossing had evidence of CREs during this period. However, only 6 (18%) had HF hospitalizations, 19 (56%) had reported changes in HF therapy, and 13 (38%) reported drug and/or dietary plan nonadherence. The average data analysis time required was 30 min daily when focusing on those with FI threshold crossing, averaging 8 uploads for review per working day and 5 telephone follow-ups per week. Our pilot observations suggested that Internet-based remote monitoring of Z trends from existing device interrogation uploads is feasible as part of a daily routine of HF disease management.
No takes yet. Share an insight, caveat, or question.
Müllens et al. (2010) conducted an observational in Heart failure. Internet-based remote intrathoracic impedance monitoring was evaluated on Feasibility and resource utilization (clinically relevant events upon fluid index threshold crossing). Internet-based remote monitoring of intrathoracic impedance trends is feasible, with 94% of patients crossing the fluid index threshold showing evidence of clinically relevant events.
Synapse has enriched 10 related papers. Consider them for comparative context: