Why the study?
Measured impedance alone was thought to have limited prognostic utility, but may have independent, additive value to OptiVol for long-term HFH risk.
Does direct measurement of intrathoracic impedance predict long-term heart failure hospitalization risk in patients with implanted devices?
Does direct measurement of intrathoracic impedance predict long-term heart failure hospitalization risk in patients with implanted devices?
Direct measurement of intrathoracic impedance from implanted devices independently predicts long-term risk of heart failure hospitalization and provides additive prognostic value to the OptiVol fluid index.
Low baseline impedance identifies higher HFH risk in device patients; leaves open whether monitoring improves outcomes.
AIMS: OptiVol fluid index was developed as a transthoracic impedance-based indicator of short-term risk for heart failure hospitalization (HFH). OptiVol is calculated as the accumulating difference between daily impedance (measured impedance) and long-term average impedance (reference impedance). Measured impedance alone was thought to have limited prognostic utility; however, measured impedance has the advantage of being simple, direct, and possibly additive to OptiVol fluid index in establishing long-term HFH risk. We tested the hypothesis that directly measured impedance has independent prognostic value in predicting long-term HFH risk and that changes in measured impedance result in a change in predicted long-term HFH risk. METHODS AND RESULTS: A retrospective analysis of 1719 patients studied in PARTNERS-HF, FAST, and RAFT studies was performed. Baseline measured impedance was determined using daily values averaged over 1 month, from Month 6 to 7 post implant; change in measured impedance was determined from values averaged over 1 month, from Month 7 to 8 post implant compared with baseline. The predictive value of baseline measured impedance for HFHs was assessed beginning 7 months post implant. The predictive value of a change in measured impedance for a change in HFHs was assessed beginning 8 months post implant. Baseline measured impedance successfully predicted HFHs. For example, 3 year HFH rate for low baseline impedance < 70 Ω was 23%; for high baseline impedance ≥ 70 Ω was 15% (P < 0.001). Changes in measured impedance resulted in changes in predicted HFHs. For example, when a baseline impedance of ≥70 fell during follow-up to <70 Ω, the subsequent HFHs were 15% compared with 4% in patients with measured impedance that remained >70 Ω (P = 0.004). In addition, when baseline measured impedance fell during follow-up by >1%, 2%, or 3%, subsequent HFHs increased to 13%, 17%, or 18%, respectively. Finally, the prognostic value of measured impedance was additive to the prognostic value of the OptiVol fluid index. CONCLUSIONS: Direct measurements of intrathoracic impedance using an implanted device can be used to stratify patients at varying risk of long-term HFH. These direct measurements of impedance have practical clinical appeal because they are simple, continuous, and ambulatory.
No takes yet. Share an insight, caveat, or question.
Zile et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: