Key result
Catheter ablation of supraventricular tachycardia in children using 3D electroanatomical mapping with limited fluoroscopy achieved an acute success rate of 95.8% and a final success rate of 100%.
Observational (n=48)
No
Answers are grounded in this paper and cite their sources.
Supports feasibility of limited-fluoroscopy 3D mapping for pediatric SVT ablation; hypothesis-generating and requires prospective confirmation.
floroskopi ile supraventrikler taikardilerin ablasyonu
No takes yet. Share an insight, caveat, or question.
Elkıran et al. (2018) conducted an observational in Supraventricular tachycardia (SVT) (n=48). Catheter ablation with 3D electroanatomical mapping (EnSite System) was evaluated on Acute success rate. Catheter ablation of supraventricular tachycardia in children using 3D electroanatomical mapping with limited fluoroscopy achieved an acute success rate of 95.8% and a final success rate of 100%.