Key result
Noninvasive assessment of intra-thoracic blood volume using dynamic magnetic resonance imaging with gadolinium chelate showed an in vitro correlation coefficient >0.99 and was feasible in volunteers.
Why the study?
Can dynamic contrast magnetic resonance imaging accurately and noninvasively measure intra-thoracic blood volume?
Can dynamic contrast magnetic resonance imaging accurately and noninvasively measure intra-thoracic blood volume?
Effect estimate: r >0.99
Dynamic contrast MRI is a feasible noninvasive method for measuring intra-thoracic blood volume, potentially replacing invasive indicator dilution techniques.
Dynamic contrast MRI is feasible for noninvasive intra-thoracic blood volume assessment in volunteers; leaves open prospective validation before clinical use.
The intra-thoracic blood volume (ITBV) is a cardiovascular parameter related to the cardiac preload and left ventricular function. Its assessment is, therefore, important for diagnosis and follow-up of several cardiovascular dysfunctions. Nowadays, the ITBV can be accurately measured only by invasive indicator dilution techniques, which require a double catheterization of the patient. In this study, a novel technique is presented for ITBV assessment by dynamic magnetic resonance imaging after intravenous injection of a small bolus of gadolinium chelate. The dose was chosen on the basis of in vitro calibration. The bolus first pass is detected from a simultaneous dynamic image series of the right and left ventricles. Two indicator dilution curves are derived and used to inspect the transpulmonary dilution system. Various mathematical models for the interpretation of the measured indicator dilution curves are compared. The ITBV is assessed as the product of the transpulmonary mean transit time of the indicator and the cardiac output, obtained by phase contrast magnetic resonance angiography. In vitro measurements showed a correlation coefficient larger than 0.99 and preliminary tests with volunteers proved the feasibility of the method, opening new possibilities for noninvasive quantitative cardiovascular diagnostics.
No takes yet. Share an insight, caveat, or question.
Mischi et al. (2009) studied this question. Dynamic magnetic resonance imaging with gadolinium chelate was evaluated on In vitro correlation coefficient (r >0.99). Noninvasive assessment of intra-thoracic blood volume using dynamic magnetic resonance imaging with gadolinium chelate showed an in vitro correlation coefficient >0.99 and was feasible in volunteers.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: