Key result
Catheter ablation of outflow tract idiopathic ventricular arrhythmias showed similar procedural success across manual (81%), contact force (71%), and magnetic navigation (92%) systems (P=0.20).
Why the study?
Does contact force or magnetic navigation system ablation improve procedural success and long-term outcomes compared to manual ablation in patients with outflow tract idiopathic ventricular arrhythmias?
Cohort (n=73)
No
Does contact force or magnetic navigation system ablation improve procedural success and long-term outcomes compared to manual ablation in patients with outflow tract idiopathic ventricular arrhythmias?
Magnetic navigation system ablation for outflow tract ventricular arrhythmias provides similar procedural success and long-term outcomes as manual and contact force ablation, but with significantly reduced fluoroscopy time.
Aims: Currently, comparative data on procedural and long-term clinical outcome of outflow tract (OT) idiopathic ventricular arrhythmia (IVA) ablation with manual (MAN), contact force (CF), and magnetic navigation system (MNS) ablation are lacking. The aim of this study was to compare the procedural and long-term clinical outcome of MAN, CF, and MNS ablation of OT IVAs. Methods and results: Seventy-three patients (31 MAN, 17 CF, and 25 MNS patients; consecutive per group) with OT IVA, who underwent catheter ablation in our centre were analysed. Procedural success rates (success at the end of the procedure), procedural data and long-term follow-up data were compared. Baseline patient demographics were comparable. Procedural success rates were similar (MAN 81%, 71% CF, and MNS 92%; P = 0.20). Median fluoroscopy time was shorter in the MNS group: MAN 29 (16-38), CF 37 (21-46), and MNS 13 (10-20) min (P = 0.002 for MNS vs. CF and MAN). The overall complication rate was: MAN 10%, CF 0%, and MNS 0% (P = 0.12). Median follow-up was: MAN 2184 (1672-2802), CF 1721 (1404-1913), and MNS 3031 (2524-3286) days (P <0.001). Recurrences occurred in MAN 46%, CF 50%, and MNS 46% (P = 0.97). Repeat procedures were performed in MAN 20%, CF 40%, and MNS 33% (P = 0.32). Conclusion: Procedural and long-term clinical outcome of OT IVA ablation are equal for MAN, CF, and MNS. MNS has a favourable procedural safety profile due to the shorter fluoroscopy time compared with MAN and CF.
No takes yet. Share an insight, caveat, or question.
Vries et al. (2018) conducted a cohort in Outflow tract idiopathic ventricular arrhythmia (n=73). Magnetic navigation system (MNS) and contact force (CF) ablation vs. Manual (MAN) ablation was evaluated on Procedural success (success at the end of the procedure) (p=0.20). Catheter ablation of outflow tract idiopathic ventricular arrhythmias showed similar procedural success across manual (81%), contact force (71%), and magnetic navigation (92%) systems (P=0.20).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: