Key result
Magnetic navigation for repeat ablation is linked to ~40% lower recurrence versus manual ablation.
Why the study?
Does a magnetic navigation system reduce recurrences and improve acute success in patients undergoing repeat catheter ablation compared to manual conventional techniques?
Cohort (n=163)
Does a magnetic navigation system reduce recurrences and improve acute success in patients undergoing repeat catheter ablation compared to manual conventional techniques?
Absolute Event Rate: 25% vs 41.4%
p-value: p=0.045
Repeat catheter ablation using a magnetic navigation system yields comparable acute success but significantly lower recurrence rates compared to manual conventional techniques.
MNS may lower recurrences after repeat ablation with comparable acute success; leaves open whether it outperforms manual techniques in randomized data.
AIMS: After initial catheter ablation, repeat procedures could be necessary. This study evaluates the efficacy of the magnetic navigation system (MNS) in repeat catheter ablation as compared with manual conventional techniques (MANs). METHODS AND RESULTS: The results of 163 repeat ablation procedures were analysed. Ablations were performed either using MNS (n = 84) or conventional manual ablation (n = 79). Procedures were divided into four groups based on the technique used during the initial and repeat ablation procedure: MAN-MAN (n = 66), MAN-MNS (n = 31), MNS-MNS (n = 53), and MNS-MAN (n = 13). Three subgroups were analysed: supraventricular tachycardias (SVTs, n = 68), atrial fibrillation (AF, n = 67), and ventricular tachycardias (VT, n = 28). Recurrences were assessed during 19 ± 11 months follow-up. Overall, repeat procedures using MNS were successful in 89.0% as compared with 96.2% in the MAN group (P = ns). The overall recurrence rate was significantly lower using MNS (25.0 vs. 41.4%, P = 0.045). Acute success and recurrence rates for the MAN-MAN, MAN-MNS, MNS-MNS, and MNS-MAN groups were comparable. For the SVT subgroup a higher acute success rate was achieved using MAN (87.9 vs. 100.0%, P = 0.049). The use of MNS for SVT is associated with longer procedure times (205 ± 82 vs. 172 ± 69 min, P = 0.040). For AF procedure and fluoroscopy times were longer (257 ± 72 vs. 185 ± 64, P = 0.001; 59.5 ± 19.3 vs. 41.1 ± 18.3 min, P < 0.001). Less fluoroscopy was used for MNS-guided VT procedures (22.8 ± 14.7 vs. 41.2 ± 10.9, P = 0.011). CONCLUSION: Our data suggest that overall MNS is comparable with MAN in acute success after repeat catheter ablation. However, MNS is related to fewer recurrences as compared with MAN.
No takes yet. Share an insight, caveat, or question.
Akca et al. (2013) conducted a cohort in Repeat catheter ablation for SVT, AF, or VT (n=163). Magnetic navigation system (MNS) vs. Conventional manual ablation (MAN) was evaluated on Overall recurrence rate (p=0.045). Repeat catheter ablation using a magnetic navigation system yielded comparable acute success but a significantly lower recurrence rate than manual ablation (25.0% vs. 41.4%, P=0.045).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: