Key result
Whole-heart radiation dose from 3D-conformal radiotherapy is not linked to cardiac events in breast cancer.
Why the study?
Radiotherapy techniques have changed substantially since earlier studies linked cardiac radiation dose to long-term cardiac disease, prompting evaluation of dose-dependent cardiac risk with contemporary radiotherapy.
Does radiation dose to the heart from contemporary 3D-conformal radiotherapy increase the risk of cardiac events in breast cancer patients?
Case-Control (n=1,482)
Yes
Does radiation dose to the heart from contemporary 3D-conformal radiotherapy increase the risk of cardiac events in breast cancer patients?
Answers are grounded in this paper and cite their sources.
Contrary to older techniques, contemporary 3D-conformal radiotherapy for breast cancer was not associated with a dose-dependent increase in the risk of cardiac events.
BACKGROUND: Previous studies with the majority of breast cancer (BC) patients treated up to 2000 provided evidence that radiation dose to the heart from radiotherapy (RT) was linearly associated with increasing risk for long-term cardiac disease. RT techniques changed substantially over time. This study aimed to investigate the dose-dependent cardiac risk in German BC patients treated with more contemporary RT. METHODS: In a cohort of 11,982 BC patients diagnosed in 1998-2008, we identified 494 women treated with 3D-conformal RT who subsequently developed a cardiac event. Within a nested case-control approach, these cases were matched to 988 controls. Controls were patients without a cardiac event after RT until the index date of the corresponding case. Separate multivariable conditional logistic regression models were used to assess the association of radiation to the complete heart and to the left anterior heart wall (LAHW) with cardiac events. RESULTS: Mean dose to the heart for cases with left-sided BC was 4.27 Gy and 1.64 Gy for cases with right-sided BC. For controls, corresponding values were 4.31 Gy and 1.66 Gy, respectively. The odds ratio (OR) per 1 Gy increase in dose to the complete heart was 0.99 (95% confidence interval (CI): 0.94-1.05, P = .72). The OR per 1 Gy increase in LAHW dose was 1.00 (95% CI: 0.98-1.01, P = .68). CONCLUSIONS: Contrary to previous studies, our study provided no evidence that radiation dose to the heart from 3D-conformal RT for BC patients treated between 1998 and 2008 was associated with risk of cardiac events.
No takes yet. Share an insight, caveat, or question.
Baaken et al. (2022) conducted a case-control in Breast cancer (n=1,482). 3D-conformal radiotherapy (per 1 Gy increase in mean heart dose) vs. Lower mean heart dose was evaluated on Cardiac events (cardiac morbidity or cardiac mortality) (OR 0.99, 95% CI 0.94-1.05, p=0.72). Radiation dose to the complete heart from 3D-conformal radiotherapy was not associated with an increased risk of cardiac events in breast cancer patients.
Synapse has enriched 10 related papers. Consider them for comparative context: