Key result
2D and 3D echo serve as the cornerstone for guiding aortic valve-sparing surgery.
Why the study?
Aortic valve-sparing surgery is increasingly used for aortic regurgitation and ascending aortic aneurysms, making practical echocardiographic evaluation essential for patient selection, predicting reparability, and assessing immediate surgical results.
2D and 3D transesophageal echocardiography are essential tools for patient selection, predicting reparability, and assessing immediate postoperative results in aortic valve-sparing surgery.
Answers are grounded in this paper and cite their sources.
Echocardiography informs aortic valve-sparing decisions; leaves open prospective multicenter validation of standardized protocols.
Owing to its excellent long-term results, aortic valve-sparing surgery is increasingly used in patients with aortic regurgitation and/or ascending aortic aneurysm. Moreover, in patients with a bicuspid valve who meet the criteria for replacement of the aortic sinuses or aortic regurgitation surgery, valve-sparing surgery may be considered if performed at a comprehensive valve center (Class 2b indication in both the American and European guidelines). Reconstructive valve surgery aims at restoring a normal aortic valve function and a normal aortic root shape as well. Echocardiography plays a central role in defining abnormal valve morphologies, in quantifying aortic regurgitation and mechanisms, and in appreciating tissue valve quality and surgical results. Therefore, despite the emergence of other tomographic techniques, 2D and 3D echocardiography represents the cornerstone for patient selection and prediction of the probability of a reliable repair. The present review focuses on echocardiographic evaluation to detect aortic valve and aortic root abnormalities, to quantify aortic valve regurgitation, to predict aortic valve reparability, and to assess immediate postoperative results in the operating room. Echocardiographic predictors of successful valve and root repair are presented in a practical way.
No takes yet. Share an insight, caveat, or question.
Lemaire et al. (2023) conducted a review in Aortic regurgitation and/or ascending aortic aneurysm. Echocardiography (2D and 3D TEE) was evaluated. Two-dimensional and three-dimensional echocardiography represent the cornerstone for patient selection, prediction of reliable repair, and intraoperative assessment in aortic valve-sparing surgery.
Synapse has enriched 10 related papers. Consider them for comparative context: