Key result
Logarithmic-transform correlation improves detection of abnormal LV function by ~10% over conventional GLS algorithms.
Why the study?
Traditional echocardiography strain analysis depends on user inputs and chamber segmentation, leading to increased measurement variability.
Does the logarithmic-transform correlation (LTC) method improve the accuracy of global longitudinal strain estimation compared to conventional methods in pediatric patients with and without cardiomyopathy?
Observational (n=54)
No
Does the logarithmic-transform correlation (LTC) method improve the accuracy of global longitudinal strain estimation compared to conventional methods in pediatric patients with and without cardiomyopathy?
Answers are grounded in this paper and cite their sources.
The automated logarithmic-transform correlation method improves the accuracy of global longitudinal strain estimation and better distinguishes between normal and abnormal left ventricular function compared to conventional algorithms.
We present a new method for measuring global longitudinal strain and global longitudinal strain rate from 2D echocardiograms using a logarithmic-transform correlation (LTC) method. Traditional echocardiography strain analysis depends on user inputs and chamber segmentation, which yield increased measurement variability. In contrast, our approach is automated and does not require cardiac chamber segmentation and regularization, thus eliminating these issues. The algorithm was benchmarked against two conventional strain analysis methods using synthetic left ventricle ultrasound images. Measurement error was assessed as a function of contrast-to-noise ratio (CNR) using mean absolute error and root-mean-square error. LTC showed better agreement to the ground truth for strain (𝑹 𝟐 = 𝟎. 𝟗1) and strain rate (𝑹 𝟐 = 𝟎. 85) as compared to conventional algorithms (strain (𝑹 𝟐 = 𝟎. 07) , strain rate (𝑹 𝟐 = 𝟎. 07)) and was unaffected by CNR. A 200% increase in strain measurement accuracy was observed compared to the conventional algorithms. Subsequently, we tested the method using a 54-subject clinical cohort (20 subjects diseased with cardiomyopathy, 34 healthy controls). Our method distinguished between normal and abnormal left ventricular function with an AUC = 0.85, a 10% improvement over the conventional GLS algorithms.
No takes yet. Share an insight, caveat, or question.
Meyers et al. (2021) conducted an observational in Cardiomyopathy (n=54). Logarithmic-transform correlation (LTC) method vs. Conventional speckle tracking echocardiography (STE) algorithms was evaluated on Area under the curve (AUC) for distinguishing normal and abnormal left ventricular function using peak GLS (p=<0.05). The logarithmic-transform correlation method distinguished between normal and abnormal left ventricular function with an AUC of 0.85, a 10% improvement over conventional global longitudinal strain algorithms.
Synapse has enriched 10 related papers. Consider them for comparative context: