Key result
Early Impella placement significantly reduced the composite of in-hospital mortality and complications compared to late bailout placement (17.1% vs 59.3%, P<0.001).
Why the study?
Does early Impella placement improve in-hospital and 1-year outcomes compared to late bailout placement in all-comer patients requiring the device?
Cohort (n=262)
No
Does early Impella placement improve in-hospital and 1-year outcomes compared to late bailout placement in all-comer patients requiring the device?
Early implantation of an Impella device is associated with significantly lower in-hospital MACCE and 1-year mortality compared to late bailout use.
Supports early Impella consideration in observational data; leaves open whether RCTs will confirm benefit.
BACKGROUND: There are non-randomized data about the benefits of Impella use in the setting of cardiogenic shock. However, limited data exist to help guide clinicians about whether in the context of the intervention the device should be implanted early or late; how long the device should stay in; and how the mode of explant should be. METHODS: This is a retrospective, single center registry over 5 years comparing in-hospital outcomes and 1-year mortality in all-comers who had the Impella device placed early versus those who had the device placed late as a bailout. The primary endpoint was a composite of in-hospital all-cause mortality, major vascular, bleeding complications, and stroke. A secondary endpoint was 1-year mortality. RESULTS: Of 262 total patients, 181 (69.1%) had early and 81 (30.9%) had late Impella placement. Patients in the early group had a lower combined MACCE (17.1% vs 59.3%, P < 0.001) and in-hospital mortality (8.8% vs 48.1%, P < 0.001) compared to the late group. Major vascular (3.3% vs 2.5%, P = 1.0), bleeding complications (5.0% vs 7.4%, P = 0.57), and stroke (3.3% vs 7.4%, P = 0.20) were not significant between groups. Early Impella placement had lower 6 month (17.7% vs 53.1%, P < 0.001) and 1-year mortality rates (21.5% vs 53.1%, P < 0.001) compared to those in the late group. CONCLUSION: For patients with need for an Impella device, regardless of the indication, early implantation is associated with better in-hospital and 1-year outcomes as compared to when the device is implanted late as a bailout.
No takes yet. Share an insight, caveat, or question.
Lazkani et al. (2017) conducted a cohort in Cardiogenic shock requiring Impella support (n=262). Early Impella placement vs. Late Impella placement (bailout) was evaluated on Composite of in-hospital all-cause mortality, major vascular, bleeding complications, and stroke (p=<0.001). Early Impella placement significantly reduced the composite of in-hospital mortality and complications compared to late bailout placement (17.1% vs 59.3%, P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: