Key result
High-frequency stimulation at 10 V was more likely to elicit an autonomic response for ganglionated plexus localization compared with 5 V, independent of contact force.
Why the study?
Does voltage threshold or contact force affect the likelihood of an autonomic response during high-frequency stimulation of ganglionated plexuses in patients with atrial fibrillation?
Observational (n=16)
Does voltage threshold or contact force affect the likelihood of an autonomic response during high-frequency stimulation of ganglionated plexuses in patients with atrial fibrillation?
During high-frequency stimulation for ganglionated plexus mapping, an autonomic response is more likely at 10 V than 5 V, and significant endocardial contact force is not required for localization.
Answers are grounded in this paper and cite their sources.
May support 10 V for ganglionated plexus mapping in AF ablation; leaves open impact on outcomes.
AIMS: The intrinsic cardiac nervous system consists of ganglionated plexuses (GPs) localized epicardially to specific regions of the left atrium (LA). The relation between voltage thresholds and endocardial contact force associated with autonomic effects during stimulation of GPs has not previously been evaluated. METHODS AND RESULTS: Sixteen patients with symptomatic atrial fibrillation (AF) underwent mapping of GPs prior to radiofrequency ablation of AF. Pre-acquired computed tomographic images were merged with 3D non-fluoroscopic electroanatomic mapping of the LA. Using high-frequency stimulation (HFS), the voltage thresholds of GPs was obtained while patients received conscious sedation. At each location, the contact force measurement from the catheter was correlated with the voltage applied during HFS at 5, 10, or 15 V to obtain an autonomic effect, usually associated with asystole, or marked bradycardia. There were 192 applications of HFS, resulting in GP identification in all patients (mean 3.4 per patient, range 1-5). During HFS, an autonomic response was significantly more likely to occur at 10 V as compared with 5 V (P < 0.008). There was no significant relation between the measured contact force and the likelihood of obtaining an autonomic response. When performing HFS at 15 V, a sudden overshoot with maximal values of contact force of up to 100 g was also observed. High-frequency stimulation was well tolerated, without associated adverse events. CONCLUSION: An autonomic response during HFS was significantly more likely to occur at 10 V as compared with 5 V. Although the GPs are epicardial structures, significant contact force was not required for their localization.
No takes yet. Share an insight, caveat, or question.
Lemery et al. (2015) conducted an observational in Symptomatic atrial fibrillation (n=16). High-frequency stimulation (HFS) vs. 5 V vs 10 V was evaluated on Autonomic response (asystole or marked bradycardia) and relation to contact force (p=< 0.008). High-frequency stimulation at 10 V was more likely to elicit an autonomic response for ganglionated plexus localization compared with 5 V, independent of contact force.
Synapse has enriched 10 related papers. Consider them for comparative context: