The study highlights significant environmental and observer effects on blood pressure measurement and reveals poor community blood pressure control among middle-aged men in the UK.
Answers are grounded in this paper and cite their sources.
Measurement conditions affect BP values; leaves open whether poor community control rates are accurately estimated.
A blood pressure measurement was part of a cardiovascular screening examination of 8397 middle-aged men taking part in the intervention section of the United Kingdom Heart Disease Prevention Project. Standardised training techniques reduced observer bias to acceptable limits in four out of a total of five observers. The time of day and room temperature both made significant differences to the blood pressure measurement. High room temperatures in particular apparently had a marked effect in reducing the level of blood pressure. There were consistent and large positive associations with increasing age and overweight. The survey revealed a poor degree of blood pressure control in the community at the time of screening--only 7% of the "hypertensive" population had their diastolic pressure controlled to below 100 mm Hg.
No takes yet. Share an insight, caveat, or question.
Heller et al. (1978) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: