An extremely low temporal noise and wide dynamic range CMOS image sensor is developed using low-noise transistors and high gray-scale resolution (17b) folding-integration/cyclic analog-to-digital converter (ADC). Two types of pixel are designed. One is a high conversion gain (HCG) pixel with removing the coupling capacitance between the transfer gate and the floating diffusion, and the other is a pixel for wide dynamic range (WDR) CMOS imager with a native transistor as a source follower amplifier. The CMOS image sensor that is in combination with the proposed pixels and the high performance column ADC has achieved a low pixel temporal noise of 1.1e rms - , a wide dynamic range of 87.5 dB with the video rate operation (30 Hz) and the vertical fixed pattern noise of 1.08-μVrms. The implemented HCG CMOS imager and WDR CMOS imager using 0.18 μm technology have the pixel conversion gain of 73.2- and 22.8-μV/e - , respectively.
No takes yet. Share an insight, caveat, or question.
Seo et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: