Key result
A deep learning model using color Doppler echocardiography clips successfully identified patent ductus arteriosus in preterm infants, achieving a study-level AUC of 0.93 (95% CI 0.89-0.98).
Why the study?
Patent ductus arteriosus is common in preterm infants and diagnosed primarily by echocardiography, prompting the training of a deep learning model to identify PDA presence in echocardiographic images.
Does a deep learning model accurately identify patent ductus arteriosus in echocardiography clips of preterm infants?
Observational (n=66)
Does a deep learning model accurately identify patent ductus arteriosus in echocardiography clips of preterm infants?
Effect estimate: AUC 0.93 (95% CI 0.89-0.98)
A novel deep learning model demonstrated strong performance in classifying echocardiography clips with and without patent ductus arteriosus in preterm infants.
May aid automated PDA screening in preterm infants; leaves open prospective validation before clinical use.
Objectives Patent ductus arteriosus (PDA) is a vascular defect common in preterm infants and often requires treatment to avoid associated long‐term morbidities. Echocardiography is the primary tool used to diagnose and monitor PDA. We trained a deep learning model to identify PDA presence in relevant echocardiographic images. Methods Echocardiography video clips (n = 2527) in preterm infants were reviewed by a pediatric cardiologist and those relevant to PDA diagnosis were selected and labeled (PDA present/absent/indeterminate). We trained a convolutional neural network to classify each echocardiography frame of a clip as belonging to clips with or without PDA. A novel attention mechanism that aggregated predictions for all frames in each clip to obtain a clip‐level prediction by weighting relevant frames. Results In early model iterations, we discovered training with color Doppler echocardiography clips produced the best performing classifier. For model training and validation, 1145 such clips from 66 patients (661 PDA+ clips, 484 PDA− clips) were used. Our best classifier for clip level performance obtained sensitivity of 0.80 (0.83–0.90), specificity of 0.77 (0.62–0.92) and AUC of 0.86 (0.83–0.90). Study level performance obtained sensitivity of 0.83 (0.72–0.94), specificity of 0.89 (0.79–1.0) and AUC of 0.93 (0.89–0.98). Conclusions Our novel deep learning model demonstrated strong performance in classifying echocardiography clips with and without PDA. Further model development and external validation are warranted. Ultimately, integration of such a classifier into auto detection software could streamline PDA imaging workflow. This work is the first step toward semi‐automated, bedside detection of PDA in preterm infants.
No takes yet. Share an insight, caveat, or question.
Erno et al. (2023) conducted an observational in Patent ductus arteriosus (n=66). Deep learning model (convolutional neural network) was evaluated on Study level classification of PDA presence (AUC 0.93, 95% CI 0.89-0.98). A deep learning model using color Doppler echocardiography clips successfully identified patent ductus arteriosus in preterm infants, achieving a study-level AUC of 0.93 (95% CI 0.89-0.98).