Key result
Automated signal quality model classifies neonatal heart sounds with ~93% accuracy, improving heart rate estimation.
Why the study?
Low quality of digital chest sound recordings complicates remote monitoring and diagnosis, particularly for neonatal care.
Observational (n=76)
An automated signal quality assessment model can accurately distinguish high and low quality neonatal chest sounds, improving the reliability of heart and breathing rate estimation for telehealth applications.
Answers are grounded in this paper and cite their sources.
May support automated quality checks for neonatal telehealth monitoring; leaves open prospective validation before clinical use.
With advances in digital stethoscopes, internet of things, signal processing and machine learning, chest sounds can be easily collected and transmitted to the cloud for remote monitoring and diagnosis. However, low quality of recordings complicates remote monitoring and diagnosis, particularly for neonatal care. This paper proposes a new method to objectively and automatically assess the signal quality to improve the accuracy and reliability of heart rate (HR) and breathing rate (BR) estimation from noisy neonatal chest sounds. A total of 88 10-second long chest sounds were taken from 76 preterm and full-term babies. Six annotators independently assessed the signal quality, number of detectable beats, and breathing periods from these recordings. For quality classification, 187 and 182 features were extracted from heart and lung sounds, respectively. After feature selection, class balancing, and hyperparameter optimization, a dynamic binary classification model was trained. Then HR and BR were automatically estimated from the chest sound and several approaches were compared.The results of subject-wise leave-one-out cross-validation, showed that the model distinguished high and low quality recordings in the test set with 96% specificity, 81% sensitivity and 93% accuracy for heart sounds, and 86% specificity, 69% sensitivity and 82% accuracy for lung sounds. The HR and BR estimated from high quality sounds resulted in significantly less median absolute error (4 bpm and 12 bpm difference, respectively) compared to those from low quality sounds. The methods presented in this work, facilitates automated neonatal chest sound auscultation for future telehealth applications.
No takes yet. Share an insight, caveat, or question.
Grooby et al. (2020) conducted an observational in Neonatal chest sounds (n=76). Dynamic binary classification model for signal quality assessment vs. Low quality sounds was evaluated on Signal quality classification accuracy and median absolute error for heart and breathing rate estimation. An automated signal quality assessment model classified neonatal heart sounds with 93% accuracy, and high-quality sounds reduced median absolute error for heart rate estimation by 4 bpm.