Sirolimus-eluting stents significantly reduced angiographic restenosis compared with bare thin-strut stents (8.3% vs 25.5%; RR 0.33; 95% CI 0.19-0.56; P<0.001).
RCT (n=500)
randomly assigned
Does a sirolimus-eluting stent reduce angiographic restenosis compared to a thin-strut bare metal stent in patients with coronary artery disease?
Sirolimus-eluting stents significantly reduce angiographic restenosis and target vessel revascularization compared to thin-strut bare metal stents, particularly in smaller vessels.
Effect estimate: RR 0.33 (95% CI 0.19-0.56)
Absolute Event Rate: 8.3% vs 25.5%
p-value: p=<0.001
AIM: Drug-eluting stents have considerably reduced restenosis. Their relative merits have been assessed on the basis of comparisons made with control bare stents with thick struts. However, increased strut thickness negatively affects restenosis. No direct comparisons between drug-eluting stents and bare stents with thin struts have been performed. The aim of this study was to evaluate the relative efficacy of sirolimus-eluting stents (Cypher) as compared with that of bare stents with thin struts (BeStent 2). METHODS AND RESULTS: A total of 500 patients with coronary artery disease were randomly assigned to receive a Cypher stent or BeStent. The primary endpoint was angiographic restenosis defined as a stenosis diameter > or = 50% at 6-month angiographic follow-up. The secondary endpoint was the need for target vessel revascularization (TVR) during the year following the procedure. Follow-up angiography was performed in 81.8% of the patients. Patients treated with Cypher stents had a lower angiographic restenosis rate [8.3 vs. 25.5%, relative risk, 0.33 (95% confidence interval, 0.19-0.56), P or = 2.8 mm), angiographic restenosis rates were 10.0% with the Cypher stent and 13.1% with the BeStent (P=0.52). CONCLUSION: The drug-eluting stent, Cypher, is associated with a significantly lower risk of restenosis compared with the bare thin-strut BeStent. The advantage of the Cypher stent is vastly reduced in large vessels.
Pache et al. (Mon,) conducted a rct in coronary artery disease (n=500). sirolimus-eluting stents (Cypher) vs. bare stents with thin struts (BeStent 2) was evaluated on angiographic restenosis defined as a stenosis diameter >= 50% at 6-month angiographic follow-up (RR 0.33, 95% CI 0.19-0.56, p=<0.001). Sirolimus-eluting stents significantly reduced angiographic restenosis compared with bare thin-strut stents (8.3% vs 25.5%; RR 0.33; 95% CI 0.19-0.56; P<0.001).