Key result
CARTO 3-guided 3D transseptal puncture safely facilitates LV endocardial lead implantation after tricuspid valve replacement.
Why the study?
Ventricular lead implantation is difficult after tricuspid valve replacement due to right atrial abnormalities that complicate conventional coronary sinus lead placement, necessitating safe alternatives for LV endocardial lead implantation.
Does left ventricular endocardial lead implantation via total three-dimensional transseptal puncture provide a safe and effective pacing method in a patient with a mechanical tricuspid valve and right atrial enlargement?
Case Report (n=1)
No
Does left ventricular endocardial lead implantation via total three-dimensional transseptal puncture provide a safe and effective pacing method in a patient with a mechanical tricuspid valve and right atrial enlargement?
Total 3D transseptal puncture guided by the CARTO 3 system offers a feasible and safe approach for left ventricular endocardial lead implantation in patients with prior tricuspid valve replacement and right atrial enlargement.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for 3D-guided transseptal LV endocardial pacing after tricuspid replacement; larger studies needed before clinical consideration.
Background: Ventricular lead implantation is relatively difficult for patients with bradyarrhythmia after tricuspid valve replacement. Right atrial (RA) abnormalities often occurred in patients with tricuspid valve disease; conventional coronary sinus (CS) lead implantation is not easy to operate. Therefore, it is necessary to develop a safe method for implanting LV endocardial leads in patients after tricuspid valve replacement. Case presentation: A 76-year-old Asian woman who had been implanted with a metal tricuspid valve replacement 4 years ago was admitted to the Department of Cardiology for pacemaker implantation due to transient blackout related to persistent atrial fibrillation with long pauses. The patient's family rejected the surgical placement of an epicardial LV lead. Therefore, we first intended to operate LV lead implantation through the CS; however, the orifice of the CS was virtually difficult to seek. Ultimately, we utilized total 3-dimensional (T3D) transseptal puncture (TSP) under the guidance of the CARTO 3 system; thus, we implanted the LV endocardial lead, which contributed to the accurate puncture of the central fossa ovalis and ensured the safety of TSP in the case of RA enlargement. Meanwhile, the CARTO 3 system contributed to the localization of the LV lead to the LV free wall during implantation. All the intraoperative and postoperative pacemaker parameters were favorable; no intraoperative or postoperative complications occurred. Conclusions: This case report may provide a novel surgical approach for LV lead implantation in patients who underwent tricuspid valve replacement or patients who may benefit from cardiac resynchronization therapy but failed to implant CS lead.
No takes yet. Share an insight, caveat, or question.
Gao et al. (2023) conducted a case report in Bradyarrhythmia after tricuspid valve replacement (n=1). Left ventricular endocardial lead implantation via total three-dimensional transseptal puncture under CARTO 3 system guidance was evaluated on Successful implantation and pacing parameters. Total three-dimensional transseptal puncture under CARTO 3 guidance successfully facilitated left ventricular endocardial lead implantation without complications in a patient with prior tricuspid valve replacement.
Synapse has enriched 10 related papers. Consider them for comparative context: