Key result
Biventricular endocardial pacing improves acute biventricular hemodynamic response over conventional epicardial pacing.
Why the study?
Does biventricular endocardial pacing improve right and left ventricular acute hemodynamic response compared to conventional epicardial pacing in heart failure patients with suboptimal CRT response?
Does biventricular endocardial pacing improve right and left ventricular acute hemodynamic response compared to conventional epicardial pacing in heart failure patients with suboptimal CRT response?
Biventricular endocardial pacing provides superior acute hemodynamic improvements in both the left and right ventricles compared to conventional epicardial pacing in patients with heart failure.
Answers are grounded in this paper and cite their sources.
Supports endocardial pacing evaluation in suboptimal CRT; leaves open whether acute gains improve clinical outcomes.
BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular epicardial (BV-CS) or endocardial left ventricular (LV) stimulation (BV-EN) improves LV hemodynamics. The effect of CRT on right ventricular function is less clear, particularly for BV-EN. Our objective was to compare the simultaneous acute hemodynamic response (AHR) of the right and left ventricles (RV and LV) with BV-CS and BV-EN in order to determine the optimal mode of CRT delivery. METHODS: Nine patients with previously implanted CRT devices successfully underwent a temporary pacing study. Pressure wires measured the simultaneous AHR in both ventricles during different pacing protocols. Conventional epicardial CRT was delivered in LV-only (LV-CS) and BV-CS configurations and compared with BV-EN pacing in multiple locations using a roving decapolar catheter. RESULTS: Best BV-EN (optimal AHR of all LV endocardial pacing sites) produced a significantly greater RV AHR compared with LV-CS and BV-CS pacing (P < 0.05). RV AHR had a significantly increased standard deviation compared to LV AHR (P < 0.05) with a weak correlation between RV and LV AHR (Spearman rs = -0.06). Compromised biventricular optimization, whereby RV AHR was increased at the expense of a smaller decrease in LV AHR, was achieved in 56% of cases, all with BV-EN pacing. CONCLUSIONS: BV-EN pacing produces significant increases in both LV and RV AHR, above that achievable with conventional epicardial pacing. RV AHR cannot be used as a surrogate for optimizing LV AHR; however, compromised biventricular optimization is possible. The beneficial effect of endocardial LV pacing on RV function may have important clinical benefits beyond conventional CRT.
No takes yet. Share an insight, caveat, or question.
Hyde et al. (2016) studied Heart Failure with suboptimal response to Cardiac Resynchronization Therapy (n=9). Biventricular endocardial pacing (BV-EN) vs. Conventional epicardial pacing (LV-CS and BV-CS) was evaluated on Acute hemodynamic response (AHR) of the right and left ventricles (p=<0.05). Biventricular endocardial pacing produced significantly greater increases in both left and right ventricular acute hemodynamic response compared to conventional epicardial pacing.