Key result
Education and EHR adaptations are linked to decreased indiscriminate POC troponin testing and ~$669,000 annual savings.
Why the study?
Point-of-care troponins have shown inconsistent accuracy compared to laboratory testing, and inappropriate use to rule out acute coronary syndrome can lead to premature diagnostic closure.
Does a quality improvement initiative reduce indiscriminate point-of-care troponin testing and costs in ED patients evaluated for ACS?
Observational
Does a quality improvement initiative reduce indiscriminate point-of-care troponin testing and costs in ED patients evaluated for ACS?
Answers are grounded in this paper and cite their sources.
A quality improvement initiative successfully reduced indiscriminate point-of-care troponin testing, leading to significant cost savings and optimized disposition times despite longer laboratory turnaround times.
BACKGROUND AND OBJECTIVES: Assessment of acute coronary syndrome (ACS) has pressured rapid diagnostic evaluation through point of care troponins (POCT-Tns). However, POCT-Tns have demonstrated inconsistent accuracy compared to laboratory (LABT)-Tn. A POCT-Tn used inappropriately to "rule-out" ACS can lead to premature diagnostic closure. We aimed to minimize indiscriminate POCT-Tn testing, while balancing test turnaround time (TAT), institutional cost, and impact on patient time to disposition (TTD). METHODS: A quality improvement (QI) initiative from 2018 to 2022 included educational interventions and electronic health record (EHR) adaptations. We evaluated test characteristics, trended test frequency, TATs, cost, and TTD. We used statistical process control charts to evaluate changes in test frequency over time. We used the Mann-Whitney U and Wilcoxon Signed-Rank Sum test to analyze changes in TAT, TTD, and cost. RESULTS: POCT-Tn had high discordance with LAB-Tn (9.7%) and low sensitivity (52.5%). SPCs showed a significant decrease in POCT-Tn tests performed over time. LABT-Tn TATs were longer than POCT-Tn (54 vs 21 min; P < .001). Total Tn testing costs decreased by $668 827.83 annually. Compared to pre-initiative, arrival to disposition was 20 min longer for patients receiving a LABT-Tn (P < .001) and 37 min shorter for patients receiving a POCT with reflex to LABT-Tn (P < .001). CONCLUSION: POCT-Tn test characteristics may place patients at risk for missed ACS. A combined approach using education and EHR adaptations decreased use of indiscriminate POCT-Tn tests, decreased health care costs, and resulted in clinically appropriate changes in disposition times for this large cohort of ED patients.
No takes yet. Share an insight, caveat, or question.
Grabinski et al. (2025) conducted an observational in Acute coronary syndrome (ACS). Quality improvement initiative (education and EHR adaptations) vs. Pre-initiative was evaluated on Test frequency, turnaround time (TAT), cost, and time to disposition (TTD). A quality improvement initiative using education and EHR adaptations decreased indiscriminate point-of-care troponin testing and reduced annual testing costs by $668,827.